Loading...
HomeMy WebLinkAbout238339_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10195515 PROJECT ADDRESS: 2213 N Weber Cir PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/8/2018 INITIAL REVIEW 2/21/2018 EXPIRATION 8/7/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Thom Jacobs 3. TEL: (714)791-1084 FAX: VALUATION:$50,000.00 EMAIL: thomljacobs@gmail.com FLOOD ZONE:X-0602320164JAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. See other red marks on the drawings. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.Please update the code editions on the cover sheet and sheet A-1 from 2013 to 2016 codes.The CalGreen notes to be updated to 2016 code.See red marks on the roof plan on sheet A-5.Provide updated structural calc. for BM#1. Drawing does not match the calc. for this beam size.Please indicate on the drawing if plywood is going to be over the proposed 2 X10 C.J. over the kitchen area. Then, Details # 8 & 12 on sheet SD1 to be consistence with this item. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.Show the location(s) of smoke detector(s) in each sleeping room and at a point centrally located in the corridor or area giving access to each sleeping area. A detector shall be located at each story, and both levels if sleeping area is on lower level; a detector shall be located in close proximity to the stairway when sleeping rooms are on the upper level. Show location of Carbon monoxide alarm on the floor plan. Show location of 20 x 30 inch attic access with 30-inch minimum headroom. (1209.2) Glass and glazing shall be in accordance with CBC Chapter 24. Note on the drawings all windows and doors having glazing. Indicate the type and thickness of each light of glazing on the drawings. Sliding glass doors (patio type) shall have Category II classification per CBC Section 2406.1. Show attic ventilation type, size, and location. The required ventilation area ratio is 1/150 of attic area or 1/300 of attic area, with required vapor retarder, if at least half of the vent area is provided by ventilators located more than 3 feet above eave vents providing the remaining portion of the vent area. Openings shall have ¼ inch corrosion resistant metal mesh covering.