Loading...
HomeMy WebLinkAbout238491_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10195557 PROJECT ADDRESS: 1831 S Ritchey St PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/14/2018 Racks and TI (to be clarified) INITIAL REVIEW 2/22/2018 EXPIRATION 8/13/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Melissa Foxx 3. TEL: (702)785-2998 FAX: VALUATION:$11,800.00 EMAIL: mfoxxsarmiento@tesla.com FLOOD ZONE:X-0602320277J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. A separate sheet for response may be used.Resubmit 3 corrected sets of plans.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - (OCFA) Fire Department approval on the corrected/final sets of drawings (714) 573-6126 - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuancePlease note on the drawings if existing building is equipped with sprinklered system.Occupancies storing, handling, using, and/or selling hazardous materials, liquids, and chemicals shall submit a list of all said materials, listing their quantities and how they relate to specific California Building Code Table items. Note on the Floor Plan, type and quantity of hazardous material in each area.Occupancies using hazardous materials are subject to special requirements. It is the applicant’s/owner’s responsibility, PRIOR TO SUBMITTAL, to make this known to the Building, Planning, or Fire Departments.Provide structural calculations for vertical and lateral load analysis. Incorporate results of calculations into drawings prior to re-submittal. Drawings and calculations must be signed by a California licensed Civil engineer or architect. Indicate material name to be stored on the racks .Additional plan check comments may apply. Reference Sheet HP3; note on the drawings the use of each area/room per Table 1004.3 of 2016 CBC. Exit cannot travel through storage room/ warehouse from office area. Show compliant exiting system. Building permit application indicates that there is TI as part of this permit. TI drawings are not submitted. Please clarify. Show occupant load and compliant travel distance for office area with one exit. Table 1016.2.1 For Buildings With One Exit:Maximum HeightMaximum OccupantsOf Building(Or Dwelling Units) OccupancyAbove Grade PlanePer Floor And Travel Distance A, B, E, F, M, U1 Story49 occupants and 75’ travel distance S1 Story29 occupants and 100’ travel distance(Applicable if TI is proposed) Valuation of proposed project is calculated as $ 11,800.00. A 20% of valuation of construction is required to be spent towards providing disabled access as noted in Section 11B-202. Revise the drawings to show compliance. Show both existing elements and how they will be upgraded to current standards. - An accessible entrance - An accessible route to the altered area - Accessible restrooms - Accessible telephone (if any) - Accessible drinking fountains, and - Parking, signage and alarms