Loading...
HomeMy WebLinkAbout239269_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10195794 PROJECT ADDRESS: 5 E Hutton Center Dr Unit# 1025 PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: I A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/7/2018 INITIAL REVIEW 3/8/2018 EXPIRATION 9/3/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jessica Shedarowich 3. TEL: (949)722-4129 FAX: VALUATION:$124,716.00 EMAIL: jshedarowich@waremalcomb.com FLOOD ZONE:X-0602320278J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. A separate sheet for response may be used.Resubmit 3corrected sets of plans.(when needed) Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceIndicate the scope of work under this building on the drawings.Label and note hourly fire rating of: - All corridors - Stair enclosuresShow/note ventilation requirements on the plans in accordance with the 2016 CBC and California Mechanical Code (CMC) requirements for each type of use. Note on drawings: Provide mechanical ventilation for each area/room in accordance with the 2013 California Mechanical Code.Note on drawings: Show/note LIGHTING requirements on the plans in accordance with CBC and California Electrical Code requirements for each type of useReference Sheet A0.3, please remove pictogram sign and shown on detail #20. The circle and triangle in contesting color to door to remain. Reference Sheet A4.2, show top of counter is between 28” – 34” above the finish floor and 34” maximum. Show compliance with Communication Elements and Features. Show fire alarm, audible and visible alarm in compliance with NFPA 72 and Chapter 9, Section 907.5.2.1 and 907.5.23. (Toilet rooms and Dining room). Please coordinate with electrical drawings.Tactile exit signs shall be required at the following locations: (identify location of each applicable signage on the floor plan or reflected ceiling plan. - Each exit door that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit sign with the following words as appropriate:“EXIT STAIR DOWN”“EXIT RAMP DOWN”“EXIT STAIR UP”“EXIT RAMP UP” - Each exit access door from an interior room or area to a corridor or hallway, which is required to have a visual exit sign, shall be identified by a tactile exit sign with the words “EXIT ROUTE.”It is the project designer’s/property owner’s responsibility to show compliance on the drawings with all applicable Federal and State Accessibility Standards. City of Santa Ana does not have jurisdiction to enforce ADA compliance and it is the responsibility of designer. When applicable, please remove notes referring to ADA compliance. This project is reviewed for compliance with 2016 CBC.