HomeMy WebLinkAbout239556_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10195861 PROJECT ADDRESS: 1584 E Santa Clara Ave PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/15/2018 INITIAL REVIEW 3/19/2018 EXPIRATION 9/11/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Brenda Bischak 3. TEL: (323)337-3544 FAX: VALUATION: EMAIL: thatbrendabischak@gmail.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2 corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). In the previously submitted calculations, there is no design for a 5 foot retaining wall supporting a 6 feet fence. Please provide structural calculations. Detail C shows a fence supported on sheet pile. Sheet pile is supported by the soil’s passive pressure. The sheet pile is located adjacent to a slope which reduced the amount of soil’s passive pressure significantly. Provide structural calcs. for the condition provided, in addition, provide soil’s recommendations for the placement of the sheet pile next to the slope. The soil’s report should indicate at what depth below the surface should the soil’s passive pressure be taken into consideration.