HomeMy WebLinkAbout237910_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10195378 PROJECT ADDRESS: 1800 E McFadden Ave PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/24/2018 INITIAL REVIEW 2/11/2018 EXPIRATION 7/23/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Behrad Kovcheri 3. TEL: (714)576-9802 FAX: VALUATION:$578,421.00 EMAIL: Architect16@pironadg.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS GENERAL REQUIREMENTSThe drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2016 California Building Standards Code with local amendments.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.All persons preparing plans and specificationsshall sign those plans and specifications. This requirement applies to both exempt and non-exempt projects. Business and Professions Code Chapter 3, Division 3, Section 5536.1(a).Include address and telephone number of the responsible designer, and date of signing of drawings.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 714-647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:☒Planning Division approval on the corrected/final set of drawings (647-5804)☒Public Works Agency approval (647-5039)☐Fire Department approval on the corrected/final sets of drawings (647-5839 or 647-5700)☒Police Department approval on the corrected/final set of drawings (647-5840)☐School District Compliance Certificate; a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of work. Refer to the attached handout.☐County of Orange Health Department approval on the corrected/final set of drawings (667- 3600)☐Grading Permit - Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039)☒Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance☐Information Technology equipment rooms require a completed electrical plan check prior to issuance of the building permit to ensure compliance with the 2016 California Electrical Code (CEC) Article 645, Electronic Computer/Data Processing Equipment. CEC Article 645 may require fire-rated walls, floors, and ceilings for the computer room(s). For additional information, contact Mr. Scott Davis, Electrical Plan Check at (714) 647-5822.A separate Building Permit Application is required for: Each building, Each structure, Each sign, Trash enclosure(s), Fence(s), Block wall(s), Light standard(s), Pedestrian protection, Demolition, Site improvements, Storage Racks, Screen Wall for Proposed Equipment.State Division of Occupational Safety Permit (Cal/OSHA) (939-0145). A Cal/OSHA permit is required: For construction of trenches or excavations which are 5‘or deeper and into which a person is required to descend. The construction or demolition of any building, structure, false-work, or scaffolding more than three stories high or the equivalent height.Delete all notes and details from drawings that are not a part of the work to be done under the subject building permit application. Clearly indicate the scope of work on the building permit application.Revise project job description on the building permit application worksheet to reflect the work to be done under the subject building permit application.Construction drawings must clearly show all work to be done under the subject building permit application. Sheet T0.01 First Plan Check Comments:Actual floor areas exceed the allowable area per CBC Section 506.2.4. Provide an allowable area analysis per Section 508. Response: See table on Sheet. Second Plan Check Comments: Allowable area analysis per Section 508 is shown on sheet T0.01. Please read the following comments: Plan shows allowable area and height of building are based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building in accordance with Section 503.1. However, the most restrictive allowances are not being used. A mixed occupancy calculations are shown. On the first-floor ratio calculations, 4,188 sq. ft. divided by 6,000 sq. ft. is 0.70. Revise the number on table. On the first-floor ratio calculations, 511 sq. ft. divided by 13,500 sq. ft. is 0.04. Revise the number on table. On the first-floor ratio calculations, the sum of ratio calculation is 0.70+0.24+0.04=0.98. Revise the number on table. On the second-floor ratio calculations, 2,793 sq. ft. divided by 6,000 sq. ft. is 0.47. Revise the number on table. On the second-floor ratio calculations, 6,352 sq. ft. divided by 9,000 sq. ft. is 0.71. Revise the number on table. On the second-floor ratio calculations, 517 sq. ft. divided by 13,500 sq. ft. is 0.04. Revise the number on table. On the second-floor ratio calculations, the sum of ratio calculation is 0.47+0.71+0.04=1.22. The sum of ratio of 1.22 exceeds 1.0. The allowable sum of ratio shall not exceed 1.0. This is a major Code issue to address. Occupancy separation details shall be provided between mixed occupancies. Provide wall assembly details, floor-ceiling assembly details with minimum fire rating complying with Table 508.4. The maximum allowable story of A-3 occupancy on Type V-B construction is one story per Table 504.4. This is a major Code issue to address. The existing building is classified as B occupancy. The propose use of mixed occupancies is a CHANGE OF USE per building code. Structural upgrade of entire building is required per Section 407 of 2016 California Existing Building Code and Table 1604.5 of 2016 California Building Code. SecondResponse: Please see new added sheet T0.01 for Code Analysis. Third Plan Check Comments: Code Analysis has been provided on T0.01. Please see the following comments:Under allowable area calculations, equation 5-2 is chosen for calculations. Equation 5-2 is for “Single-occupancy with multistory buildings”. However, the allowable area calculations were performed using mixed occupancies. Equation 5-3 is the correct equation under Section 506.2.4.On first sheet, a hand written note indicates Storage areas and assembly areas as accessory occupancies. However, the sum of accessory spaces occupies more than 10 percent of the floor area of the story in which they are located.The aggregate actual areas on first floor and second floor do not match the first sheet. The sum of floor area on the first floor is 4622 sqft + 632 sqft + 1686 sqft = 6940 sq ft. Floor area on first sheet indicates first floor area of 9242 sq ft. The sum of floor area on the second floor is 5929sqft + 518 sqft + 1493 sqft = 7940 sq ft. Floor area on first sheet indicates second floor area of 9920sq ft. Item j & k from previous comments remain outstanding until item 2 & 3 are addressed.