HomeMy WebLinkAbout243043_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10196861 PROJECT ADDRESS: 1506 W First St PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/25/2018 INITIAL REVIEW 6/28/2018 EXPIRATION 12/22/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Chris Borland 3. TEL: (562)412-6450 FAX: VALUATION: $50,000.00 EMAIL: cborland@theolsonco.com FLOOD ZONE: X-0602320257J APPLICABLE CODE: 2016CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSPlease indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment, when needed.This review (10194056-07) does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. Please remove electrical drawings.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (714-647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings (714-573-6126) - Police Department approval on the corrected/final set of drawings (714-647-5840) - Public Works Agency approval (714-647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceIndicate existing occupancy of building 1 and 2 on the drawings and indicate distance from patio cover to each building and property line. Reference Sheet LC-3.01, Show accessible wheel chair seating for new patio cover and identify location (30”x48”) on the drawings. Reference Sheet LC-1.01. Note SF-3, Provide detail for new bench in compliance with Section 11B-903 of 2016 CBC.Reference Sheet CS-0.01, Correct Sheet index to reflect sheets numbers applicable to this project. Please void details/notes that are not applicable to this project on all Sheets.Indicate Occupancy and Type of construction for proposed patio cover and building 1 and 2 on the drawings.Reference Sheet LC-0.01, Site schedule; revise information on Curved shape structural to match structural drawings for combustible and non-combustible material as shown on structural drawings.Reference Sheet LC-3.01, Construction key note #3, “staging area for Fire department”, clarify and if applicable to this permit and remove/date notes that are not part of this permit. Obtain OCFA approval if note is applicable.Provide material specification for concrete, steel, rebar and list special inspection items including welding and anchor bolts. Reference page 10 of geotechnical item #6.2, Seismic Design Parameters, Revise Table 6.1 to show compliance with 2016 CBC (not 2013 CBC).