HomeMy WebLinkAbout242746_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10296781 PROJECT ADDRESS: 1257 S Cedar St PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/18/2018 INITIAL REVIEW 7/10/2018 EXPIRATION 12/15/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Everett Smith 3. TEL: (951)323-2187 FAX: (951)823-5365 VALUATION: $25,000.00 EMAIL: everettdrew@hotmail.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Provide a 1 hour detail for walls closer than 5 feet to the property line, provide an approval number for the detail.( Cross reference with the plans) Provide a water proofing detail/flashing at the garage above the ledger.(where is it on the plans) Provide a statement as to the scope of work under this permit. The scope specified on the plans does not match with what is proposed. Show clearly at a section the elevation of the proposed patio enclosure. Please make sure all you drawing are legible, I.e. the ink is not faded. Provide a section of the slab, shoe the sand/gravel and the visqueen. On Foundation plan show clearly all new foundation. Specify the size of the footing underneath the garage wall supporting the ledger. Provide a detail to clarify what is existing and what is new. Provide information on plans to show that the existing house rooms adjacent to the proposed addition have adequate light and ventilation. THE TITLE 24- CALCS PROVIDED ARE FOR A DIFFERENT PROJECT, PROVIDE PROPER TITLE-24 CALCS. THE MANDATORY REQUIREMENTS ARE NOT LEDGIBLE.