HomeMy WebLinkAbout244515_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10197280 PROJECT ADDRESS: 1220 W Hemlock Way Unit# 107 PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/7/2018 INITIAL REVIEW 8/17/2018 EXPIRATION 2/3/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Kelly Lee 3. TEL: (949)724-8958 FAX: VALUATION:$71,940.00 EMAIL: Klee@saaia.com FLOOD ZONE:X-0602320259J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS .Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. A separate sheet for response may be used.1. All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checkerResubmit 3corrected sets of plans. Please refer to mark up set of drawings for additional plan check comments. Return marked up set of drawings with corrections.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only, if needed. This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (714-647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (714-647-5840) - Public Works Agency approval (714-647-5039)Orange County Fire Authority approval on the corrected/final sets of drawings (714-573 - 6126)Proof of Worker’s Compensation Insurance shall be required at the time of permit issuancePlease refer to red marks on the drawings for additional plan check comments. Revise drawings to show compliance with red marks including plan check report.Reference Sheet A-0.1, correct the following information’s:Type of construction to V-BIf existing building is equipped with Sprinklered or to be installed.Provide scope of work “Drawing index” to remove MEP SheetsLabel, 1st.floor as part of this permit onlyVoid/delete accessibility details that do not apply to this project.Reference Sheet A-0.5, please refer to red marks and provide additional information including identifying the path of travel, ramp slope, cross slope, railing, and location of truncated dome and flowing comments:Clarify path of accessible path of travel on the drawings and indicate slope (5% max) and cross slop (2% max.) on the drawings.Identify 6” high curb/walkway separating from vehicle traffic area. Provide truncate domes where applicable. If a walk crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings or other elements (at zero curb) between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning which is 36” wide. Detectable Warning Product Approval. Only approved Division of the State Architect, Access Compliance (DSA/AC) approved detectable warning products and directional surfaces shall be installed in accordance with CBC Section 705.1 of 2016 CBC.At every entrance and at every major junction along or leading to an accessible route of travel, there shall be a sign displaying the international symbol of accessibility. Signs shall indicate the direction to accessible building entrances and facilities. Show location of path of travel including slope and cross slop on the drawings. Reference Sheet A-0.7. Provide completely dimensioned floor plan of actual layout of all existing toilet rooms to show accessibility compliance and show calculations based on Table 402 of 2016 CBC. Reference Sheet A-0.7; please remove pictogram from signage for toilet door circle and triangle signs. Reference Sheet a-0.8, show compliance with followings:show door landing and accessible path of travel for existing exit doorsRevise wall legend to identify all wall type shown on floor plan Sheet a-0.8. Additional plan check comments may apply. Add occupant load of waiting area 101 to exit analysisLabel floor plan as 1st floor. Identify existing and new fire rated corridor and please note if building is or is not equipped with Sprinklered system determining the fire rating of corridor. Correct Detail 5 on Sheet A-9.0 and show location of smoke and fire rated damper if rated corridor is needed.Show required clearances for exit door adjacent to perception room 100 including door closures at 180 degree and accessible door clearance for reception door 100. Please refer to plan check comments for accessible door for additional comments. Submit a letter addressed to Building department to clarify new Use of class room and waiting area and associated offices. Please note plan check comments are based on B occupancy and additional plan check comments to flow if change of occupancy is proposed. Reference Sheet A-20.0, show accessible counter height at 28” minimum and 34” maximum for accessibility compliance including reception desk employ side and client side as well. For proposed card readers show compliance with section 1010.1.9.7, 20160CBC for each item listed and show location of each card reader on the drawings. Show accessible height for card reader installed by doors, Show/note ventilation requirements on the plans in accordance with the CBC and California Mechanical Code (CMC) requirements for each type of use. Note on drawings:- Provide mechanical ventilation for each area/room in accordance with the 2016 California MechanicalCode.Note on drawings:Show/note LIGHTING requirements on the plans in accordance with CBC and California Electrical Code.Valuation of proposed project is calculated as $71,940.00. A minimum of 20% of valuation of construction is required to be spent towards providing disabled access as noted in CBC Chapter 11-B, Division 2. Drawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC 11-B, Division 2. - An accessible entrance - An accessible route to the altered area - Accessible restrooms - Accessible telephone (if any) - Accessible drinking fountains, and - Parking, signage and alarmsPlease refer to attached accessibility form and return completed Form to Building department.It is the project designer’s/property owner’s responsibility to show compliance on the drawings with all applicable Federal and State Accessibility Standards. City of Santa Ana does not have jurisdiction to enforce ADA compliance and it is the responsibility of designer. If applicable, please remove note/s referring to ADA compliance. This project is reviewed for compliance with 2016 CBC.Provide drawings to show compliance with following items;All doors require a level floor landing on each side Provide typical door threshold details (1/2” max threshold) and when applicable provide details of change in floor covering materialThe width of the level area on the side to which the door swings shall extend 24” past the strike edge of the door for exterior doors and 18” past the edge for interior doors. All building entrances that are accessible to and usable by persons with disabilities shall be identified with a least one standard sign and with an additional directional signs, as required, to be visible to persons along approaching pedestrian ways.Hand-activated door opening hardware shall be centered between 34” and 44” above the floor. Latching and locking doors that are hand activated and which are in a path of travel shall be operable with a single effort by lever-type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Locked exit doors shall operate as above in egress direction. Note on the drawings: “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding doors. Provide specifications for doors hardware (i.e., lever type, push-pull panic, etc.) to comply with disabled access requirements. Revise door schedule to include accessibility compliance. All building entrances that are accessible to and usable by persons with disabilities shall be identified with a least one standard sign and with an additional directional signs, as required, to be visible to persons along approaching pedestrian ways.Required the bottom 10” of all doors except automatic and sliding shall have a smooth uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition.Tactile exit signs shall be required at the following locations: (identify location of each applicable signage on the floor plan or reflected ceiling plan.- Each grade-level exterior exit door shall be identified by a tactile exit with the word “EXIT.” - Each exit access door from an interior room or area to a corridor or hallway, which is required to have a visual exit sign, shall be identified by a tactile exit sign with the words “EXIT ROUTE.”Provide parking data on the site plan showing the total number of parking spaces is required and provided for proposed project and show required number of disabled accessible spaces and the number of van accessible spaces on the drawings. Surface slopes of accessible parking spaces shall be the minimum possible and shall not exceed 1-unit vertical to 48 units horizontal (2% slope) in any direction.Disabled accessible parking spaces should be sized as follows: Where single spaces are provided, they shall be a 9’ wide parking area with an outlined 5’ wide (8’ wide for van accessible space) loading and unloading aisle ON THE PASSENGER SIDE E VEHICLE. The minimum length of each parking space shall be 18’. The loading and unloading access aisles shall be marked by a border painted blue. Within the blue border, hatched lines a maximum of 36” on center, shall be painted a color contrasted with the parking surface, preferably blue or white. Parking access aisles shall be part of an accessible route of travel to the building or facility entrance. Parked vehicle overhangs shall not reduce the clear width of an accessible route. The words NO PARKING shall be painted on the ground within each loading and unloading access aisle. This notice shall be painted in white letters no less than 12” high and located so that it is visible to traffic enforcement officials. When more than one space is provided, two 9’ wide parking areas may be outlined on each side of a 5’ wide (8’ wide for van accessible space(s)) loading and unloading aisle. The minimum length of each parking space shall be 18’. The loading and unloading access aisles shall be marked by a border painted blue. Within the blue border, hatched lines a maximum of 36” on center, shall be painted a color contrasted with the parking surface, preferably blue or white. Parking access aisles shall be part of an accessible route of travel to the building or facility entrance. Parked vehicle overhangs shall not reduce the clear width of an accessible route. The words NO PARKING shall be painted on the ground within each loading and unloading access aisle. This notice shall be painted in white letters no less than 12” high and located so that it is visible to traffic enforcement officials.Provide parking space identification in accordance with CBC Section 11B-222 including: Each parking space reserved for persons with physical disabilities shall be identified by a reflecting sign permanently posted immediately adjacent to and visible from each stall or space, consisting of a profile view of a wheelchair with occupant in white on dark blue background. The sign shall not be smaller than 70 square inches in area and, when in path of travel, shall be posted at a minimum height of 80” from the bottom of the sign to the parking space finished grade and shall be un-obscured by a parked vehicle. Signs may also be centered on the wall at the interior end of the parking space. An additional sign or additional language below the symbol of accessibility shall state “Minimum Fine $250.” An additional sign stating “Van Accessible” mounted below the symbol of accessibility. An additional sign shall also be posted in a conspicuous place at each entrance to off-street parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall not be less than 17” by 22” in size with lettering not less than 1” in height, with clearly and conspicuously states the following: Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards license plates issued for persons with disabilities may be towed away at owner’s expense. Provide assurance on the drawings that existing signage language reflects the paragraph above. Vehicles may be reclaimed by telephoning the Santa Ana Police Department at (714) 245-8665. CVC 22658a.