Loading...
HomeMy WebLinkAbout239617_2_Corrections.docx PLAN CHECK NO: 10195873 PROJECT ADDRESS: 2335 W First St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/19/2018 INITIAL REVIEW 5/2/2018 EXPIRATION 9/15/2018 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Esber Samaan 3. TEL: (949)542-0996 FAX: VALUATION:$58,200.00 EMAIL: esbersamaan@gmail.com FLOOD ZONE:X-0602320257JINSTRUCTIONS: Numbersinbracketsrefertocodesectionsof 2016CaliforniaBuilding Code[CBC],2016CaliforniaPlumbingCode[CPC],2016CaliforniaMechanicalCode[CMC],2016California ElectricalCode[CEC],2016CaliforniaEnergyCode(2016BuildingEnergyEfficiencyStandards[BEES]),and2016 CaliforniaGreenBuildingsStandardsCode[CalGreen] Correctoriginaldrawings.Reprintandsubmit3newsetstogetherwiththe“marked-up”set.Returnthiscorrections list with corrected plans. In the Item number column, ☒ in the checkbox represents correction requested. IntheRespondcolumn,pleaseindicatethesheetnumberanddetailornote numberontheplanwherethe corrections are made. Itemize anychanges,revisions,oradditions madeto drawingsthatarenotadirectanswertoa correctionona separate sheet. Additionalplancheckfeewill be requiredafterthirdreviewonhourlyrate basis. PART I: GENERAL REQUIREMENTS PERMIT APPLICATIONS Item # Sheet # Corrections Requested Respond Provide valuation on Building Permit Worksheet ☐ Valuation is too low. Submit a signed copy of the contract showing labor and materials for all work to be done. ☐ Provide complete information for applicant, owner, engineer, architect, and contractor. Obtain separate permit for the following items: Retaining walls or block fence walls, Grading work, Signs, Swimming pools, Fire sprinkler systems, Separate structure, Electrical, Mechanical, Plumbing work, Shoring, and Demolition. The permit application must be signed by the property owner, or licensed contractor, or authorized agent at the time the permit is to be issued: ☐ For owner-builder permits: Owner’s signature can be verified with owner’s driver license. Owner’s representatives must present owner’s approval with a notarized letter from the owner. ☐ For contractor building permits: Prior to the issuance of a building permit, the contractor shall have the following: ☐ Certificate of workers Compensation Insurance made out to the Contractors State License Board ☐ Notarized letter of authorization for agents ☐ Copy of Contractors State License or pocket ID ☐ Copy of City of Santa Ana business tax registration certificate or a newly paid receipt for one. CLEARANCES Item # Sheet # Corrections Requested Respond Obtain approvalfromthefollowingdepartments prior to building permit issuance: Planning Department (714-647-5804) Public Works Department (714-647-5039) ☐ Fire Department (714-647-5839) ☐ Police Department (714-647-5840) ☐ School District County of Orange Health Department (714-667-3600) ☐ Provide temporary shoring plans for excavations removing the lateral support of public way or an existing building. Excavations adjacent to a public way require Public Works approval prior to permit issuance. ☐ Where the depth of excavation is greater than the walls or foundation of an adjoining building, the owner shall provide the Department of Building and Safety with evidence that the adjacent property owner(s) have been given a 30-day written notice of such intent to make an excavation. This notice shall state the depth of such excavation and when it will commence. This notice shall be by certified mail, return receipt requested. ☐ Submitgradingplan forreview.Gradingapprovalisrequiredbeforebuilding permit will beissued. ☐ Provide Soilreportfor review. PART II: BUILDING CODE Walk-In Cooler/ Freezer Item # Sheet # Corrections Requested Respond Site Plan Scale and north arrow. Max. scale 1"= 40'(Preferred scale is 1" = 20' or 1" = 40') Dimensions of lot, distance to property lines,location(s) and square footage of existing or proposed structures, street name, location and use. Condensing units located on buildingexterior must be shown on site plan. Floor Plan (scale: 1/4"= 1' or 1/8"= 1') Indicate location of all exits. Required exitdoors must be not less than 3’ in width and not less than 6 feet 8 inches in height. Provide exiting details showing compliance with CBC Sec. 1014, 1015, and 1016 and Chapter 11 ☐ Show location and specify dimensions ofproposed walk-in cooler or freezer. General Provide information regarding productsstored, including packaging, shelving, and sprinkler design information (i.e. density, area of coverage and temperature rating of heads). Mechanical Provide refrigeration equipment productdata specifying listing approvals and weights. Show location of compressors, condensers,and other equipment. Specify amount and type of refrigerant. Structural Design Provide framing plans and calculations, forvertical and lateral loads, stamped by a California State registered professional engineer for any roof mounted equipment weighing more than 400 pounds. Units weighing less than 400 pounds (when directly supported on framing members larger than 2 x 4) are not required to be stamped by an engineer. Roof curb designs must be provided for allroof mounted mechanical equipment. If factory curbs will be used, provide details. Specify the type, amount, and location of fasteners. All floor supported mechanical equipmentand fixed appliances shall be anchored to the structure to resist displacement vertically and on both horizontal axis due to seismic motion. Specify anchorage for floor sup- ported equipment on the plans. Suspended mechanical equipment and appliances shall have rigid vertical hangers and be braced in both horizontal directions. Connections by pipes or ducts that are or contain non-rigid elements, are not of inherent sufficient strength, or which are not adequately anchored will not be acceptable as equipment or appliance anchors. Detail anchorage for suspended equipment on drawings. Foam Plastic Insulation The interior of the building shall be separatedfrom foam plastic insulation by an approved- thermal barrier that complies with CBC Sec.2603.6.4. Provide manufacturer’s name, productlisting, product identification and information to show that the proposed structure com- plies with the flame-spread andsmoke-development limitations of CBC Sec.2603. ADDITIONALCORRECTIONS: Item # Sheet # Corrections Requested Respond ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐