HomeMy WebLinkAbout244493_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10197275
PROJECT ADDRESS:
6 E Hutton Center Dr Unit# 1000
PLAN CHECK ENGINEER:
Heidari, FredTEL:714
647-5862FAX:714
647-5897
TYPE OF CONSTRUCTION:
I A, SPK
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/7/2018
INITIAL REVIEW
8/14/2018
EXPIRATION
2/3/2019
RECHECKS:
1. 09/06/2018
PROJECT APPLICANT CONTACT PERSON:
2.
Jessica Shedarowich
3.
TEL:
(949)788-4129
FAX:
VALUATION:$350,000.00
EMAIL:
jshedarowich@waremalcomb.com
FLOOD ZONE:X-0602320278J
The recheck of your drawings is completed this morning, 09-06-2016; and they are approved for building permit issuance subject to approvals listed under item # 6 from the list below.
The approved drawings is placed at the plan check counter for your convenience.
APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceCBC Section 1008.2.1, Requires means of egress from all occupied parts of the building be provided with at least 1’ candle of light at floor level. Show compliance on the drawings.Glass shall be firmly supported on all four edges. Show on the drawings how compliance shall be made with CBC Sections 2403.2., 2403.3 and 2403.4. For glass not firmly supported on all four edges, design shall be submitted to the building official for approval.