HomeMy WebLinkAbout240756_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10196209 PROJECT ADDRESS: 1217 S Linda Way PLAN CHECK ENGINEER: Mazarji, ZacTEL:714 647-5831FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/23/2018 279 S.F. of 1st floor addition INITIAL REVIEW 6/5/2018 EXPIRATION 10/20/2018 RECHECKS: 1.8-27-18 PROJECT APPLICANT CONTACT PERSON: 2. Rudy Morales 3. TEL: (951)290-2733 FAX: VALUATION: $31,429.00 EMAIL: rm@tmred.space FLOOD ZONE: X-0602320257JRecheck: 8-27-18Show compliance with Items 20 and 21 of plan check comments with review date of 6-5-18 (see plan check comments below). Pleas call 714-647-5831 for over the Counter meeting when comments are addressed and drawings are revised. APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original drawings.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment, if needed. Please see corrections on submitted plans. Red marked set must be returned with revised plans. All final drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (714-647-5804). Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.All new construction, interior or exterior alterations, repairs, or additions requiring a permit and having a valuation in excess of $1,000, or when one or more sleeping rooms are added or created, the entire dwelling shall be provided with smoke detectors located as required for a new dwelling. (CRC R314.3)All new construction, Interior or exterior alterations, repairs, or additions requiring a permit and having a valuation in excess of $1,000,, an approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel-burning appliances are installed and in dwelling units that have attached garages shall be provided with carbon monoxide alarms (CRC R315)Interior spaces intended for human occupancy shall be provided with heating facilities capable of maintaining a room temperature of 68 degrees Fahrenheit at a point 3 feet above the floor and 2 feet from exterior walls in all habitable rooms. (CRC R303.8)Private garage shall be separated from the residence and its attic by a minimum ½ -in gypsum board applied to the garage side. Show location of rated wall on the drawings. Private garage shall be separated from the residence, Provide the minimum 1-3/8 inch solid-core wood door, a solid or honeycomb core steel door not less than 1-3/8 inch thick, or a 20-minute fire rated door between the garage and residence unless both are protected by an automatic residential fire sprinkler system. (CRC R302.5.1) Callout attic vent locations, sizes and types on plans. Provide attic ventilation calculation to show minimum ventilation is provided. (CRC R806.2).The total net free ventilating area shall not be less than 1/150 or 1/300 when a Class I or II vapor barrier is installed on the warm-in-winter side of the ceiling. (CRC R806.2) Provide existing and proposed contours/spot elevations to indicate general site slope and drainage pattern. (CBC 107)Fireblocking is required in concealed spaces 10’ o.c. horizontal, vertically at the ceiling and floor levels, connections between horizontal and vertical spaces, concealed spaces between stair and landing, openings around vents, pipes, ducts, cables, wires, chimneys and fireplaces. (CRC R302.11)Provide a minimum access of 22 x 30 inches attic access and show location on architectural and roof framing plan. Access shall be provided to all under-floor spaces. The floor access shall be a minimum 18” by 24” and openings through a perimeter wall shall be not less than 16” by 24”. (CRC R408.4) Also showthe minimum net area of under-floor space ventilation shall not be less than the floor area/150. For ventilation. Show location/s on the drawings.(CRC R408.1) Refer to attached 2016 CalGreen Forma and provide a copy on the drawings. Please complete each Form and paste on each set of drawings. Refer to attached SB 407 information Sheet and show compliance on the drawings. The residence shall conform to the State Energy Conservation Standards. TheDesigner and Documentation Author cannot be the same person revise T-24 calculation Sheet and on the drawings.Show required shear walls on all 4 sides of proposed addition or submit structural calculations for rotational analysis when only three side of proposed addition is provided with shear wall. Note on drawings: "Truss supplier shall submit calculations and shop drawings signed by a registered civil engineer to the responsible project designer who agrees to review the shop drawings for acceptance prior to fabrication. Shop drawings and calculations shall be submitted to the Building Safety Division for acceptance after the responsible project designer has noted his/her acceptance and prior to fabrication.” Truss drawings must reflect compliance with CBC Sections: -Plans, structural calculations, and specifications must be prepared by a California registered civil engineer. (A106.1) -Regulation of prefabricated construction including required inspections and certifications. (1703.6) -Connectors and fasteners shall be installed in accordance with CBC Section 2304.9. -Metal-plate-connected wood trusses shall conform to CBC Section 2303.4. Provide evidence of required fabrication, storage, handling and delivery inspections. -When bearing studs are spaced at 24-inch intervals and top plates are less than two 2-inches by 6-inches, and when trusses are spaced at more than 16” intervals, such trusses shall bear within 5” of the studs beneath or a third top plate shall be installed. (2308.9.2.2) -The ICC approved agency number must be noted on shop drawings. Note on the drawings for new trusses as deferred submittal. Separate submittal and plan review through Building department is required. Reference Sheet A3.0, detail 8, remove detail and provide a correct connection detail on structural Sheets. Reference Sheet SD2, submit structural calculations for design and justification for existing roof truss when subject to additional roof load by new trusses.