HomeMy WebLinkAbout244957_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10297426
PROJECT ADDRESS:
502 S Birch St
PLAN CHECK ENGINEER:
Chehade, NabilTEL:714
647-5848FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/20/2018
INITIAL REVIEW
9/2/2018
EXPIRATION
2/16/2019
RECHECKS:
1.10/9/2018
PROJECT APPLICANT CONTACT PERSON:
2.
Melissa Baker
3.
TEL:
(951)352-3588
FAX:
VALUATION: $10,000.00
EMAIL:
Info@powellandassoc.com
FLOOD ZONE: X-0602320276J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
Please clarify what is going on with the window that is being whited out. The room need to have adequate light and ventilation either natural or mechanical. Show clearly if there will be a window or if it is being removed.
Please note for a window to have light and ventilation from an adjacent room the common wall has to be a minimum of 50% open.
Structural calcs show a 2x8 rafters, submitted plans are showing a 2x6? Please revise or justify.
The design load used In the calculations to justify the 2X6 at 24” o.c. is lower than the tabulated loads. In addition please clarify how the allowable bending stress is arrived at. Further, clarify the deflection calcualtions and what values are used( you might have to perform a hand calc. to justify that the deflection is ok. (2x6 at 24” spanning 9 feet seems in adequate, can use 2x6 at 12” or 2x8.
Provide title 24 calculation including the mandatory measures on the plans.
Using 2X8 fascia and 2x8 blocking with the 2x6 rafters seems inappropriate.