HomeMy WebLinkAbout242337_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10196659
PROJECT ADDRESS:
5127 W Edinger Ave Unit# D
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
A-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
6/7/2018
INITIAL REVIEW
6/24/2018
EXPIRATION
12/4/2018
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Ken Fang
3.
TEL:
(909)569-2069
FAX:
VALUATION:$88,314.00
EMAIL:
CND9@me.com
FLOOD ZONE:X-0602320256JINSTRUCTIONS:
Numbersinbracketsrefertocodesectionsof 2016CaliforniaBuilding Code[CBC],2016CaliforniaPlumbingCode[CPC],2016CaliforniaMechanicalCode[CMC],2016California ElectricalCode[CEC],2016CaliforniaEnergyCode(2016BuildingEnergyEfficiencyStandards[BEES]),and2016 CaliforniaGreenBuildingsStandardsCode[CalGreen]
Correctoriginaldrawings.Reprintandsubmit3newsetstogetherwiththe“marked-up”set.Returnthiscorrections list with corrected plans.
In the Item number column, ☒ in the checkbox represents correction requested.
IntheRespondcolumn,pleaseindicatethesheetnumberanddetailornote numberontheplanwherethe corrections are made.
Itemize anychanges,revisions,oradditions madeto drawingsthatarenotadirectanswertoa correctionona separate sheet.
Additionalplancheckfeewill be requiredafterthirdreviewonhourlyrate basis.
Second Review Comments
Plumbing fixture calculations are shown on sheet A-1. The occupant load factor for the purpose of calculating plumbing fixtures is based on California Plumbing Code Table A, not exiting requirement as stated. Revise occupant load calculations.
One urinal is required in men’s restroom. however, a urinal is missing in the restroom. Per Table 422.1 Footnote 3, the total number of required water closets for females shall be not less than the total number of required water closets and urinals for males. In other words, if one urinal and one water closet are required for male, two water closets are required for female. Only one water closet is shown in women’s restroom. Based on the required plumbing fixture calculations, additional urinal is required in men’s restroom and additional water closet isrequiredin women’s restroom.