Loading...
HomeMy WebLinkAbout248792_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10198562 PROJECT ADDRESS: 1975 E Seventeenth St PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/4/2018 INITIAL REVIEW 12/16/2018 EXPIRATION 6/2/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jeff Coffman 3. TEL: (714)738-7045 FAX: VALUATION:$10,000.00 EMAIL: jeff@jeffcoffmanarchitect.com FLOOD ZONE:X-0602320164J APPLICABLE CODE: 2010 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSpecify the type of material to be stored and the type of construction and occupancy group of the proposed addition.If the shed is of a different type of construction including being non-sprinklered, it should be separated from the other building by a fire wall. Please note that even though the tilt-up wall is fire rated, it does not meet the other criteria for firewall.Provide a ledger detail including the hardware. Provide an ESR number for any wedge or chemical anchors.Provide an allowable area analysis to show that the proposed addition will still be within the required allowable area. .