HomeMy WebLinkAbout248281_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10198402 PROJECT ADDRESS: 4001 W Carriage Dr Unit# A PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830FAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): B, F-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/19/2018 INITIAL REVIEW 12/2/2018 EXPIRATION 5/18/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Julia Chang 3. TEL: (213)388-6642 FAX: VALUATION:$15,000.00 EMAIL: julia@dgbamerica.com FLOOD ZONE:X-0602320258J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS GENERAL REQUIREMENTSThe drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2016 California Building Standards Code with local amendments.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.All persons preparing plans and specificationsshall sign those plans and specifications. This requirement applies to both exempt and non-exempt projects. Business and Professions Code Chapter 3, Division 3, Section 5536.1(a).Include address and telephone number of the responsible designer, and date of signing of drawings.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 714-647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:☒Planning Division approval on the corrected/final set of drawings (647-5804)☒Public Works Agency approval (647-5039)☐Fire Department approval on the corrected/final sets of drawings (647-5839 or 647-5700)☒Police Department approval on the corrected/final set of drawings (647-5840)☐School District Compliance Certificate; a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of work. Refer to the attached handout.☐County of Orange Health Department approval on the corrected/final set of drawings (667- 3600)☐Grading Permit - Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039)☒Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance☐Information Technology equipment rooms require a completed electrical plan check prior to issuance of the building permit to ensure compliance with the 2016 California Electrical Code (CEC) Article 645, Electronic Computer/Data Processing Equipment. CEC Article 645 may require fire-rated walls, floors, and ceilings for the computer room(s). For additional information, contact Mr. Scott Davis, Electrical Plan Check at (714) 647-5822.A separate Building Permit Application is required for: Each building, Each structure, Each sign, Trash enclosure(s), Fence(s), Block wall(s), Light standard(s), Pedestrian protection, Demolition, Site improvements, Storage Racks, Screen Wall for Proposed Equipment.State Division of Occupational Safety Permit (Cal/OSHA) (939-0145). A Cal/OSHA permit is required: For construction of trenches or excavations which are 5‘or deeper and into which a person is required to descend. The construction or demolition of any building, structure, false-work, or scaffolding more than three stories high or the equivalent height.Delete all notes and details from drawings that are not a part of the work to be done under the subject building permit application. Clearly indicate the scope of work on the building permit application.Revise project job description on the building permit application worksheet to reflect the work to be done under the subject building permit application.Construction drawings must clearly show all work to be done under the subject building permit application.PLAN REVIEW COMMENTSSheet T1.1Revise the type of construction to “III-B” under Construction Summary.Specify occupancy groups under Construction Summary. Cultivation spaces shall be classified as factory occupancy (F-1) and offices as business occupancy (B).Revise note B under Project Description. City of Santa Ana does not enforce ADA Title III laws and regulations. Revise the governing standards to “2016 California Building Code – Chapter 11B” on note B.Provide the following note under Applicable Codes: “City of Santa Ana Municipal Code”.Sheet A1.1Provide two accessible parking spaces as required by Table 11B-208.2. One in every six or fraction of six parking spaces required by Section 11B-208.2 Minimum Number, but not less than one, shall be served by an access aisle96 inches wide minimum placed on the side oppositethe driver’s side when the vehicle is going forward into the parking space and shall be designated “van accessible”. All such spaces may be grouped on oneLevel of a parking structure. §11B-208.2.4, 11B-502, Fig 11B-502, 11B-502.3, & 11B-502.3.3Accessible parking spaces complying with Section 11B-502 Parking Spaces serving a particular building or facility shall be located on the shortest accessible route of travel from adjacent parking to an accessibleEntrance (as near as practical to an accessible entrance). §11B-208.3.1See checklist below on accessible parking requirement. ☐ Dimension minimum 18-foot long car and van accessible parking space(s) and access aisle(s). §11B-502.2, Figures 11B-502.2 and 11B-502.3 ☐ Dimension minimum 9-foot width at accessible car parking space. §11B-502.2, Fig. 11B-502.2 & Fig.11B-502.3 ☐ Dimension minimum 12-foot wide accessible van parking space with minimum 5-foot wide access aisle. Van parking spaces shall be permitted to be minimum 9 feet wide where access aisle is 8-foot wide minimum.§11B-502.2, Figures 11B-502.2 and 11B-502.3 ☐ Car and van stall access aisle shall be 5 foot wide minimum and shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle. §11B-502.3, Figures 11B-502.2 and11B-502.3 ☐ Access aisles shall be marked with a blue painted borderline around their perimeter. The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches on center in a color contrasting with that of the aisle surface, preferably blue or white. The words "NO PARKING" shall be painted on the surface within each access aisle in white letters a minimum of 12 inches in height and located to be visible from the adjacent vehicular way. Access aisle markings may extend beyond the minimum required length. §11B-502.3.3, Figure 11B-502.3.3 ☐ Access aisles shall not overlap the vehicular way.Access aisles shall be permitted to be placed on either side of the parking space except for van parking spaces which shall have access aisles located on the passenger side of the parking spaces. §11B-502.3.4 ☐ Clearly show minimum vertical clearance of 8 feet 2 inches at accessible parking spaces and along at least one vehicle access route to such spaces from site entrances and exits. §11B-502.5 ☐ Parking space identification signs shall include the International Symbol of Accessibility complying with Section11B-703.7.2.1 International Symbol of Accessibility. §11B-502.6, Figure 11B-703.7.2.1 ☐ Signs identifying van parking spaces shall contain additional language or an additional sign with the designation “van accessible.” Signs shall be 60 inches minimum above the finish floor or ground surface measured to the bottom of the sign. §11B-502.6 ☐ Parking identification signs shall be reflectorized with a minimum area of 70 square inches. §11B-502.6.1 ☐ Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250.” §11B-502.6.2 ☐ A parking space identification sign shall be visible from each parking space. Signs shall be permanently posted either immediately adjacent to the parking space or within the projected parking space width at the head end of the parking space. Signs may also be permanently posted on a wall at the interior end of the parking space. §11B-502.6.3 ☐ Each accessible car and van space shall have surface identification complying with either of the following schemes: §11B-502.6.4 ☐ The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 International Symbol of Accessibility in white on a blue background a minimum 36 inches wide by 36 inches high. The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches from the centerline of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower side aligned with, the end of the parking space length. §11B-502.6.4.1 ☐ The parking space shall be outlined or painted blue and shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 International Symbol of Accessibility a minimum 36 inches wide by 36 inches high in white or a suitable contrasting color. The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches from the centerline of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower side aligned with, the end of the parking space. §11B-502.6.4.2 ☐ An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space. §11B-502.8 ☐ The additional sign shall not be less than 17 inches wide by 22 inches high. §11B-502.8.1 ☐ The additional sign shall clearly state in letters with a minimum height of 1 inch the following: §11B-502.8.2 "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or special license plates issued for persons with disabilities will be towed away at the owner’s expense. Towed vehicles may be reclaimedby telephoning the Santa Ana Police Department at (714) 245-8665. CVC 22658a. ☐ Signs intended for use by pedestrians within parking facilities, including directional or informational signsindicating parking sections or levels, shall comply with the requirements of Section 11B-216. §11B-216.5.2Sheet A2.1What is the fire rating of existing demising wall between existing warehouse area and proposed T.I. area? The required fire rating of the demising wall is dependent on existing or proposed use of adjacent tenant space.Show 18-inches strike-edge dimension at doorway inside the Feed-Tank Room and doorway outside of Secured Storage room.Specify opening-doorway dimension at the corridor near the Floor R&D room.Show travel egress distance from the most remote location (Grow Room #1) to the exit.Calculate the total number of occupant load and the required exit width. Show the provided exit width at doorways exceeds the required exit width.Sheet A4.1Revise dimensional line on grab bars measured from the floor to top of grab bar. Drawings shows dimensional line measure to the center line of grab bar, which is technically not compliant to Code.Cross reference restroom signage detail on the restrooms floor plan.Show 30”x48” clear floor space in front of the sink in both male and female restroom on the floor.