Loading...
HomeMy WebLinkAbout250641_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10199142 PROJECT ADDRESS: 2369 N Riverside Dr PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/7/2019 INITIAL REVIEW 2/11/2019 EXPIRATION 8/6/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Edgar Lopez 3. TEL: (714)463-0123 FAX: VALUATION: EMAIL: elopezdesigns@hotmail.com FLOOD ZONE: X-0602320163JResubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.The Engineering of records shall provide structural calculation and construction details for changing the roof framing from pre-fab trusses to conventional frame roof. Also, details # 1, 2, 3, & 4 on sheet SD2 and detail # 5/SD3 shall be modified to reflect changes in roof framing.