REMARKS/RECHECK ITEMS:
APPLICATION
2/21/2019
INITIAL REVIEW
3/14/2019
EXPIRATION
8/20/2019
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Lindsey Engels
3.
TEL:
(714)308-4089
FAX:
VALUATION:$40,221.00
EMAIL:
Lindsey@arclogica.com
FLOOD ZONE:X-0602320259JAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.
All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered engineer. The structural drawings to be signed and the note: “FOR REFERENCE ONLY- NOT FOR CONSTUCTION” shall be removed from the structural sheets. All persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a).Detail 4/1-A8.1 to be updated to show 8” separation of wood from grade.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.]
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840).
-Public Works Agency approval (647-5039).
-Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
Show compliance with CRC Section R302.1 and Table R302.1 (1) for eave of the proposed addition. Provide 1 Hour fire resistance rating on the undersideShow the location(s) of smoke detector(s) in each sleeping room and at a point centrally located in the corridor or area giving access to each sleeping area. See CRC Section R314.Show the location(s) of Carbon monoxide alarm on the drawings. See CRC Section R315.
The residence shall conform to the State Energy Conservation Standards. Submit forms and calculations for review and blueprint the final forms on the plans.
-Signed Energy Efficiency Documents must be printed on the plans.
-Also, submit 2 copies of signed Energy Efficiency calculations.
-The permit applicant shall be responsible for obtaining an energy plan check from a consultant
who is qualified to perform an energy efficiency analysis in accordance with the California Code
of Regulations (CCR), Title 24, Part 1 (Administration) and Part 6 (2016 California Energy Code).
The plan check consultant must sign documentation certifying that a thorough, competent review
has been performed on behalf of the Enforcement Agency.
-The corrected/final drawings shall have the required energy efficiency compliance documentation
with completed signature blocks filed on the plans.
-The energy plan check consultant must sign documentation forms on behalf of the Building
Safety Division.
-Please refer to attached Residential Lighting Design Guide and revise drawings to show
compliance.