Loading...
HomeMy WebLinkAbout251648_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10199431 PROJECT ADDRESS: 1614 E Aspen St PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/13/2019 INITIAL REVIEW 3/23/2019 EXPIRATION 9/9/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Armando Usquiano 3. TEL: (562)228-5727 FAX: VALUATION: $40,000.00 EMAIL: ausquiano29@gmail.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. No openings are allowed between the garage and the bedrooms An emergency escape window is required from the bedroom next to the living room. Provide vertical load and lateral load analysis. Plans to be signed and stamped by engineer of record. Show location of attic access. Window locations on framing plan is different from that shown on floor plans. Show the clear opening’s dimensions of the window used for egress. Provide a structural section at the ridge to show what is being done with the sintering of the ridge board? Please note a ridge beam and a bridge board is required. Provide a detail to show that the garage wall is fire rated next to living space.