Loading...
HomeMy WebLinkAbout252357_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10199654 PROJECT ADDRESS: 2424 N Valencia St PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/2/2019 INITIAL REVIEW 4/9/2019 EXPIRATION 9/29/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Logan Borzansky 3. TEL: (949)678-9462 FAX: VALUATION: EMAIL: loganborzansky@yahoo.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Resubmit 2 corrected sets of plans. This walls seems to be a bearing wall supporting the ridge beam and valleys. The previous framing plan and foundation plan showed a foundation underneath the proposed beam. Please clarify if the foundation is still a part and make sure it is a part of these plans. In addition, please provide a copy of the structural calcs for the proposed beam. Provide a section above the existing wall to justify that the wall being removed is not a shear wall.