HomeMy WebLinkAbout250110_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10198978 PROJECT ADDRESS: 914 S Austin St PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/23/2019 INITIAL REVIEW 4/12/2019 EXPIRATION 7/22/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Huy T. Nguyen 3. TEL: (714)262-3929 FAX: (714)828-4995 VALUATION: $100,000.00 EMAIL: starsconstruction@yahoo.com FLOOD ZONE: X-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2010 California Residential Code (CRC); 2010 California Building Code (CBC); CMC = 2010 California Mechanical Code; CPC = 2010 California Plumbing Code; CEC = 2010 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Dimension the width of the corridor. The smoke detector and carbon monoxide alarm need to be interconnected and hard wire, where is the specifications. I see that there is supposed to be a note number 1 somewhere? Show location of heater, if in attic, show attic layout and profile, make sure is adequate head room clearance for the furnace. Show location of house attic access. This project need to comply with the green building code, provide notes and details to show compliance. Show location of EV ready raceway per green building code. Show location of solar ready raceway per green building code. Provide a grade beam underneath all narrow simpson shear walls in garage. Provide a dimension for footing depth. Call out special inspection for epoxy anchors per the ESR report. Provide a 1-hr separation between the house and the garage. Provide detail.