HomeMy WebLinkAbout253025_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10199863 PROJECT ADDRESS: 2310 S Redhill Ave PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848FAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/22/2019 INITIAL REVIEW 5/4/2019 EXPIRATION 10/19/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Joe Hage 3. TEL: (714)348-3115 FAX: VALUATION:$30,000.00 EMAIL: joe@hoboco.com FLOOD ZONE:X-0602320279J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Public Works Agency approval (647-5039).Review by the fire department is required.Provide a profile of the tank showing the height and width.Evaluate the slab’s capacity to support the weight of the tanks. Please note the worst condition is with more than one tank set next to each other.Specify the slab thickness on plans.Plans will be left at the counter.The profile provided is inadequate, the elevation height is not specified, the units are shown in mm, and the tank legs are not shown.I tried to call the number associated with this permit application, but they said there was no Joe at that number, so I will e-mail this the e-mail address provided.