HomeMy WebLinkAbout253025_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
10199863
PROJECT ADDRESS:
2310 S Redhill Ave
PLAN CHECK ENGINEER:
Chehade, NabilTEL:714
647-5848FAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
B, F-1, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/22/2019
INITIAL REVIEW
5/4/2019
EXPIRATION
10/19/2019
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Joe Hage
3.
TEL:
(714)348-3115
FAX:
VALUATION:$30,000.00
EMAIL:
joe@hoboco.com
FLOOD ZONE:X-0602320279J
APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Public Works Agency approval (647-5039).Review by the fire department is required.Provide a profile of the tank showing the height and width.Evaluate the slab’s capacity to support the weight of the tanks. Please note the worst condition is with more than one tank set next to each other.Specify the slab thickness on plans.Plans will be left at the counter.The profile provided is inadequate, the elevation height is not specified, the units are shown in mm, and the tank legs are not shown.I tried to call the number associated with this permit application, but they said there was no Joe at that number, so I will e-mail this the e-mail address provided.