Loading...
HomeMy WebLinkAbout252953_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10199845 PROJECT ADDRESS: 1034 S Main St PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 4/18/2019 INITIAL REVIEW 4/28/2019 EXPIRATION 10/15/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Vicky Li 3. TEL: (714)906-5714 FAX: (888)473-9995 VALUATION:$44,516.00 EMAIL: vickyli8875@yahoo.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceDrawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC Section 11B-202.4- An accessible entrance - An accessible route to the altered area - Accessible restrooms - Accessible telephone (if any) - Parking, signage and alarmsIf a walk crosses or adjoins a vehicular way, and the walking surfaces are not separated by curbs, railings or other elements between the pedestrian areas and vehicular areas, the boundary between the areas shall be defined by a continuous detectable warning which is 36” wide, complying with the CBC Section 11B-247.1.2.5Complete the attached Disabled Accessibility Documentation Form.Detail 1/A-1b doesn’t match site plan.Provide path of travel from accessible parking to the building including curb ramp, slope, detectable warning ,…..Please verify if there is any alteration to the ceiling.Show height of the posts on detail 13/D-1.On detail 6/ D-1 wall cannot be supported and attached directly to the roof truss.Provide minimum 60” landing at the bathroom door.Doors shall located in the front partition or in the side wall or partition farthest from the water closet. CBC CBC 11B-604.8.1.2