Loading...
HomeMy WebLinkAbout254571_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101100346 PROJECT ADDRESS: 614 S Rosewood Ave PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848 EMAIL: Nchehade@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/6/2019 INITIAL REVIEW 7/30/2019 EXPIRATION 12/3/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Luis Arevalo 3. TEL: (714)785-7088 FAX: VALUATION: EMAIL: lantonioR80@gmail.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Plans are identified as plan revision, this is not a revision to the plan but a new scope of work. Provide a complete set of plans showing a framing plan and a construction section. The section on sheet A2.1 is miss leading, identify where the section is taken. Sheet A5 that is referenced on the plans is not provided. Provide adequate lateral resisting element to support the proposed balcony on both direction. Please either follow the prescriptive requirements in the CRC or provide structural calcs. Provide appropriate lateral support in both direction. Clarify what water proofing material is being place on top of the balcony; make sure the weight of this material is accounted for in the design of the framing members. Clearly identify on the plans which details are new part of the proposed balcony and which are existing ( part of the previous permit). Show the height of the guardrail and method of support. Show the size of any opening in the guardrail of the balcony. Show/ provide proper drainage for rainwater from the balcony. Please note that of the balcony has solid rail all around, a drain and overflow should be provided.