Loading...
HomeMy WebLinkAbout250691_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 10199154 PROJECT ADDRESS: 2333 S Evergreen St PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862FAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/7/2019 INITIAL REVIEW 6/24/2019 EXPIRATION 12/4/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jorge Torres 3. TEL: (323)345-2149 FAX: VALUATION:$17,186.00 EMAIL: FLOOD ZONE:X-0602320278JAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2016 California Building Standards Code with local amendments. All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered engineer. Or, all persons preparing plans for others shall sign those plans. Business and Professions Code Chapter 3, Division 3, Section 5536.1 (a). This review does not include electrical work. Separate plan, application, fee, plan check, and permitis required for electrical work. Call 647-5800 for information.] The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039). -Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. -Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039). Provide a fully dimensioned Site Plan on the drawings. The site plan on sheet”1” of the drawings is not clear. Specify the roof slope on the roof plan. Show location of minimum 20x30-inch attic access with 30-inch minimum headroom on the plans. Any exterior door out of this proposed garage? Show attic ventilation type, size, and location. The required ventilation area ratio is 1/150 of attic area or 1/300 of attic area, with required vapor retarder, if at least half of the vent area is provided by ventilators located more than 3 feet above eave vents providing the remaining portion of the vent area. Openings shall have ¼ inch corrosion resistant metal mesh covering. Note on the plans: "Roof diaphragm nailing to be inspected before covering. Face grain of plywood shall be perpendicular to supports." Provide structural calculations and drawings prepared by a California Licensed Architect or Registered Civil Engineer for lateral load resistance of the walls in front of the proposed garage. There are some red marks on the drawings. Please correct the drawings and resubmit them for recheck.