HomeMy WebLinkAbout255647_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101100668 PROJECT ADDRESS: 2209 S Rosewood Ave PLAN CHECK ENGINEER: Chehade, NabilTEL:714 647-5848 EMAIL: Nchehade@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/3/2019 INITIAL REVIEW 9/4/2019 EXPIRATION 12/30/2019 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Earnest Little 3. TEL: (562)686-1007 FAX: VALUATION: $191,740.00 EMAIL: earnest.midway@gmail.com FLOOD ZONE: X-0602320259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Grading permit is required, check with public works. Provide a soil’s report. Show location of space heater. Provide water proofing material for the balcony. Title24 should be done for the whole house. Add note to indicate that the Carbon monoxide alarm and the smoke alarms are interconnected and are hard wired. Provide a fan in the existing bathroom where the window has been eliminated. Show that all windows in the bedrooms comply with the emergency escape requirements. Provide stair step dimensions; run and rise. Any usable space under stair must be rated. Provide handrail dimension and picket spacing. Dimension clear width of stair. Garage must be separated from the house by fire rated drywall. Call on plans. Dimension balcony railing. Please clarify if the intention is to have a part of the garage supported on raised floor. If so, provide a detail of the transition point. The Raised floor in the garage supporting vehicle need to be designed for the vehicle load. Specify on framing plan the length of the 4X6 headers supporting the floor load. Show clearly all header support.