HomeMy WebLinkAbout256116_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101100821 PROJECT ADDRESS: 1225 E Wakeham Ave PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862 EMAIL: fHeidari@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/19/2019 INITIAL REVIEW 7/31/2019 EXPIRATION 1/15/2020 RECHECKS: 1. 08/21/2019 PROJECT APPLICANT CONTACT PERSON: 2. 08/22/2019 Chris Kane 3. TEL: (949)351-2945 FAX: VALUATION: $81,000.00 EMAIL: ckane@ice-energy.com FLOOD ZONE: X-0602320276J Your drawing was approved for building permit issuance subject to approvals required under item # 8 from the list below. The approved drawings are placed at the plan check counter for your convenience. A recheck of your drawing was completed this morning, 08-21-2019; and the following items from the first plan check list are not done/ completed at this time. See the list below for item # 6, 7, & 8. Called the structural engineer for this project, ED NAJJARINE, and left a message this morning. APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2016 California Building Standards Code with local amendments.Provide structural calculations and drawings, stamped and signed by a California licensed architect or registered civil engineer for: - New equipment screening on roof if it is required by Planning Division. - The drawings shall clearly show framing members under these 5500 # “Ice Bear” units and show how VERTICAL AND LATERAL LOADS will be distributed to existing roof framing members. (Any proposed reinforcement of existing 2 X 4 @ 24” O.C. under these Ice Bear unitsThis review does not include mechanical, plumbing, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance