Loading...
HomeMy WebLinkAbout256404_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101100907 PROJECT ADDRESS: 300 W Fifth St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/29/2019 INITIAL REVIEW 9/23/2019 EXPIRATION 1/25/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Bernard Martinez 3. TEL: (714)519-8342 FAX: VALUATION: $89,750.00 EMAIL: imp7@earthlink.net FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet ID-1 shows proposed new wall at the new bar area near the entrance. Provide structural details of the new wall. Show structural connection of the wall to the foundation and the structural support at the top of the wall.Sheet ID-1 shows accessible seating at the new bar area. Provide the following details for knee-and-toe clearances at the seating area: Specify the following dimensions on elevation drawing. The minimum and maximum dimension implies construction tolerance is not permitted. (11B-606.2): Knee clearance is the spacebetween 9-inches and 29-inches above finished floor: ☐29-inchesminimum above finished floor at front-end of lavatory. ☐27-inches minimum above finished floor at 8-inches deep. ☐At 9-inches above finished floor, extend 11-inches minimum under the lavatory. ☐At 9-inches above finished floor, extend 25-inches maximum under the lavatory. ☐Knee clearance shall be 30-inches wide minimum. Toe clearanceis the space between finished floor and 9-inches above finished floor: ☐Extend 17-inches minimumunder the lavatory. ☐Extend 19-inches maximum under the lavatory. ☐Toe clearance shall be 30-inches wide minimum.Specify the total number of seating provided in the dining area. The minimum number of wheelchair space shall be provided in the dining area shall comply with Table 11B-221.2.1.1: