Loading...
HomeMy WebLinkAbout257279_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101101167 PROJECT ADDRESS: 2800 N Main St Unit# 9060 PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: II B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/21/2019 INITIAL REVIEW 9/6/2019 EXPIRATION 2/17/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Kevin Dahlaky 3. TEL: (949)743-3633 FAX: VALUATION: $20,000.00 EMAIL: Permitsexpediting@yahoo.com FLOOD ZONE: X-0602320163J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceKiosk shall comply with CBC Section 402.6.2: - Kiosk more than 8’ high requires a design by a California licensed civil engineer or architect. - CBC Section 1604.9 and 1613. Kiosk anchorage to floor shall be by mechanical fasteners and resist all sliding and overturning forces induced by lateral forces. - Flame spread rating of kiosk construction shall comply with CBC Chapter 8. - Non-combustible materials are required for framework. 406.6.2.1Show how rolling security will be supported.Show type of the posts on the drawings.On all details call type and size of all construction members.Show cash register is in compliance with accessibility.