HomeMy WebLinkAbout259149_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101101830 PROJECT ADDRESS: 1301 E Seventeenth St PLAN CHECK ENGINEER: Heidari, FredTEL:714 647-5862 EMAIL: fHeidari@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/14/2019 INITIAL REVIEW 10/23/2019 EXPIRATION 4/11/2020 RECHECKS: 1. 11/06/2019 PROJECT APPLICANT CONTACT PERSON: 2. Lucas Teani 3. TEL: (714)786-6285 FAX: VALUATION: $75,000.00 EMAIL: lucas.teani@kimley-horn.com FLOOD ZONE: X-0602320163J A recheck of your drawings was completed this morning, 11/06/2019; and item # 7 from the list below is not done/ completed at this time. APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.This review does not include electrical work. Separate plan, application, fee, plan check, and permitis required for electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceDrawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC Sections 11B-228.3 & 11B-812: - The aisle at the vehicle space shall be marked with a painted border around their perimeter,(11B-812.7.2) - The EV chargers shall be adjacent to and within the projected width of the vehicle space being served. (11B-812.10.4) - EVCS shall be designed so accessible routes are not obstructed by cables or other elements. (11B-812.5.5)