HomeMy WebLinkAbout259376_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101101906 PROJECT ADDRESS: 1212 N Broadway PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V A OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/8/2019 INITIAL REVIEW 11/8/2019 EXPIRATION 5/6/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Mike Chalan 3. TEL: (949)439-4000 FAX: VALUATION: EMAIL: mikechalan@hotmail.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2016California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.Plan Review CommentsUpdate all structural sheets to match architectural layout. On sheet S2, label all one-hour fire rated wall between units.On sheet S2, update unit numbers according to the updated architectural plans.On sheet S3, cross reference detail number 9/SD1 at the wall between gridline E and H.On sheet S3, cross reference detail number 13/SD1 at the wall between gridline H and K.On sheet A1, specify one-hour fired rated wall between unit #109 and Recreation room.On sheet A1, specify one-hour fired rated wall between unit 112 and electrical room.On the site plan, identify electrical meter location. The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - School District Compliance Certificate; a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of work. Refer to the attached handout. - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceAny outstanding fees such as park fee, school fee shall be paid prior to building permit final.This is the second revision to the original approval. The first revision shall be voided. Please contact the Building permit counter for process and procedure.