HomeMy WebLinkAbout259190_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101101844 PROJECT ADDRESS: 2709 W Westminster Ave Unit# B PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/27/2019 INITIAL REVIEW 12/27/2019 EXPIRATION 5/25/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Joseph Rodriguez 3. TEL: (714)914-8896 FAX: VALUATION: $5,000.00 EMAIL: rodriguezjoseph577@gmail.com FLOOD ZONE: X-0602320144J APPLICABLE CODE: 2016 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please return marked up set of drawings with corrections.Sheet A1.1A portion of a common wall between suite B and suite C is being removed for the purpose of the bakery expansion. The occupancy group may be revised to a more restrictive classification if the occupant load in the bakery expansion is equal or greater than 50. If this is the case, the occupancy group will be classifying as an assembly group (A-2). A higher level of life-safety design and fire protection features are required than the current design. Provide an occupant load calculation to determine the appropriate occupancy group on this expansion project.Include installation of new beam and posts under Scope of Work.Sheet A2.2Where is existing wall between suite B and suite C in the kitchen area? Provide existing floor plan for verification.A new 4x12 beam is shown where the non-bearing wall is being removed. What is the new beam supporting?Provide structural connection detail between new posts and foundation. Detail one indicates post-size per plan. However, post size is not specified on floor plan. Provide and cross reference an enlarged accessible restroom and show all relevant accessible restroom features such as clear floor space, grab bars, and floorplan dimensions. Detail 6 on sheet ADA2-2 does not match the floor plan layout.