Loading...
HomeMy WebLinkAbout256709_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101100997 PROJECT ADDRESS: 923 1/2 W Berkeley St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/8/2019 INITIAL REVIEW 10/28/2019 EXPIRATION 2/4/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jose Salemi 3. TEL: (949)302-7336 FAX: VALUATION: $48,000.00 EMAIL: salemijr@yahoo.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2016 California Residential Code (CRC); 2016 California Building Code (CBC); CMC = 2016 California Mechanical Code; CPC = 2016 California Plumbing Code; CEC = 2016 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2010California Building Standards Code with local amendments and to clearly indicate the scope of work under this building permit application. There may be additional requirements when complete construction drawings and supporting data is submitted for Building Safety Division review.Provide one additional copy of structural calculations for approval.Sheet S3 – cross reference shear transfer detail along grid line “3”.Sheet S3 – new ceiling joists are shown in accessory dwelling units. Show roof attic ventilation location and calculations on roof plan.Sheet S2 – Specify moisture barrier underneath the concrete slab on detail F14.Sheet A6 – Specify dimensions at exterior door landing.