HomeMy WebLinkAbout262166_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101102800 PROJECT ADDRESS: 2307 N Riverside Dr PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/9/2020 INITIAL REVIEW 1/26/2020 EXPIRATION 7/7/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Eric Fulsang 3. TEL: (949)838-4139 FAX: VALUATION: $17,000.00 EMAIL: eric@fularch.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Please submit one additional set of plan for approval. For residential new construction or room additions, one additional set of plan is required for tax assessor’s office.On Sheet A-2, show exterior landing and dimensions at proposed exterior door in the kitchen area. The width of landing shall be equal or greater than the width of door opening. The dimension of landing in direction of travel shall not be less than 36 inches.On Sheet A-2, show exterior landing and dimensions at proposed exterior door in the master-bedroom area. The width of landing shall be equal or greater than the width of door opening. The dimension of landing in direction of travel shall not be less than 36 inches.On Sheet A-2, specify tempered glazing at the exterior door in the master-bedroom area.On Sheet A-7, revise elevation drawing to include the proposed closet on the second floor.On Sheet S-3, provide roof framing for proposed closet space on the second floor.