HomeMy WebLinkAbout263791_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103332 PROJECT ADDRESS: 1927 W Fifteenth St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/2/2020 INITIAL REVIEW 4/21/2020 EXPIRATION 8/29/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Dikla Shechori 3. TEL: (818)220-9452 FAX: VALUATION: $20,000.00 EMAIL: vered_nissan@hotmail.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.General:All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). Sheet T-1: Site plan: Please show surface drainage slope and pattern away from the new exterior wall foundation (5% minimum). Under General Notes: Please update applicable codes to 2019 code edition. Project Description: Please specify occupancy group R-3 / U. Please show distance between the property line and new addition. Plumbing fixtures flowrate: Please revise flowrates complying with the 2019 California Green Building Code as follow: Water closet = 1.28 gallon per flush Showerheads = 1.8 gallon per minute at 80 psi. Lavatory faucets = 1.2 gallon per minute at 60 psi. Kitchen faucet = 1.8 gallon per minute at 60 psi. Sheet A-2: Building Section – Please clarify why roof rafter (R.R) was labeled as new (N). Shingle roofing is not allowed when roof pitch is less than 2:12 slope. Please revise plan accordingly. Sheet S-1: General Structural Requirements, Building Codes: LA Building Code is not applicable to projects under City of Santa Ana jurisdiction. Please omit/remove note. Sheet S-3: Roof framing details referenced to sheet S-5; however, sheet S-5 was not provided. Please provide sheet S-5 for construction details. (End of Comment)