PLAN CHECK NO:
102103441
PROJECT ADDRESS:
1151 W Riviera Dr
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/12/2020
INITIAL REVIEW
3/16/2020
EXPIRATION
9/8/2020
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Juanita Galliford
3.
TEL:
(714)904-0125
FAX:
VALUATION: $50,000.00
EMAIL:
JUANITA.GALLIFORD@BSHG.COM
FLOOD ZONE: AE-0602320144J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) for an appointment.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5848 for an appointment.
Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
Sheet S1. Add the following information to the scope of work on plan: Remove interior walls to relocate & remodel kitchen, bathroom, & laundry room on 1st floor.
Sheet S1. Provide following information in the scope of work:
Square footage of the Interior remodel: __ sf.
How many windows are added or altered:___
How many doors are added or altered:___
If the existing fireplace is to be removed, add this work in the scope of work.
Sheet S1. Add note to plan: Occupancy type: R3 / U
Sheet S1. Note on the Drawings:
- Number of stories:
- Existing building area:___ sf.
- Area of existing garage:___ sf.
- Area of remodel area:___ sf.
Provide building East elevation(due to elevation changes). Elevation drawings shall include following information:
- Height dimensions
- Exterior finishes and materials
- Exterior building components (walls, roof, doors, windows, etc.)
- Window types
- Window header height
Sheet S1. Provide window and door schedule. Callout sizes and types of openings and if new or existing.
Sheet S1. Provide the proposed floor plan to ¼”=1’-0” scale.
Sheet S1. Provide legible dimensions shown on the proposed floor plan. Please use __’x__” instead of __”
Sheet S1, Please remove the new proposed walls from the demo plan and highlight the new proposed walls on the proposed floor plan. (Remember to inform your structural engineer and update your structural plans)
Sheet S1. Clarify if the existing fireplace to be removed. The demo plan shows existing to remain. However, the proposed floor plan does not have the fireplace. Revise both demo and proposed floor plan to clarify and revise the scope of work on plan to add this work.
Sheet S1. Add note on plan to the mudroom and laundry room: “Where openable windows are not provided provide a mechanical ventilation system capable of producing 0.35 air change per hour in the room. (CRC R303.1 (1))”
Sheet S1. Add note on plan: Private garage shall be separated from the residence and its attic, structure(s) supporting floor/ceiling assemblies used for separation required by CRC Section R302.6. The garage shall be protected by a minimum ½-in gypsum board applied to the common wall on the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than a 5/8-in type X gypsum board. [2016 CRC R302.6].
Sheet S1. Add note on plan:Doors between the garage and private residence shall be self-closing and self-latching and 20-minute fire rated. (CRC R302.5.1)
ENERGY
Sheet S1. Add note on plan:Maximum U-factor=0.30 and maximum SHGC=0.23 for new windows and glazed doors. Exception: Replacement of vertical fenestration no greater than 75 square feet with a U-factor no greater than 0.40 and a SHGC value no greater than 0.35. (2019 CEC150.2(b).1.B Exception 1)
Sheet S1. Add note on plan: Minimum R13 insulation is required at the exterior wall infill.
Please incorporate “2019 Low-Rise Residential Mandatory Measures Summary” into plans (4 pages). Refer to the following link: https://ww2.energy.ca.gov/title24/2019standards/documents/2019_Residential_Mandatory_Measures_Summary_ADA.pdf
STRUCTURAL
Sheet S2. Please update the structural framing and foundation plans to match the proposed architectural floor plan. There are multiple openings are altered on the east exterior wall. Please update the wall layout and provide relevant structural design.
Sheet S2. Refer to grid line B (see red marks on plan), provide vertical structural design for new openings and provide lateral structural design for the lateral support. Provide structural calculation and structural details and revise structural plans.
Provide shear wall overturning calculation on the 8 feet long shear wall on grid line A. Justify if vertical tie-down is required at each end of the shear wall. When vertical tie-down is provided, type, and detail shall be on the plan.
Sheet S1 and S2. Indicate the date when the plan is signed by the license civil engineer. The date should be shown adjacent to the license stamp.