HomeMy WebLinkAbout263555_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101103253
PROJECT ADDRESS:
1901 E Dyer Rd Bldg# B
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III A, SPK
OCCUPANCY CLASSIFICATION(S):
R-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
4/21/2020
INITIAL REVIEW
5/14/2020
EXPIRATION
10/18/2020
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Keli Burton
3.
TEL:
(949)293-3018
FAX:
VALUATION: $20,000.00
EMAIL:
keli@cp-services.biz
FLOOD ZONE: X-0602320278J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.The drawings/information submitted for Building Safety Division review is incomplete. The applicant shall, prior to resubmitting, complete all construction documents to show compliance with the 2019 California Building Standards Code with local amendments.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSubmit a signed copy of the contract showing labor and materials for all work to be done under the subject building permit application. The plan check engineer may accept the contract price as the valuation of improvements for unique/unusual projects in lieu of using a cost per square foot basis.Provide the following:
- Provide a fully dimensioned site plan on each set of plans. Show location of buildings on the buildings with canopies.Provide on the drawings a complete “fire resistance design schedule” which shall include the following:
- The building elements which require fire-resistive construction.
- The hourly rating of the building element as required by the Code.
- Evidence of appropriate fire resistance for each building element in accordance with specific UL listing or ICC
Evaluation Report for each material selected. Evidence shall include appropriate material thickness for each
building element.Wood blocking cannot be used in type III-A exterior wall. Please provide material and I-hr fire rated detail for blocking per section 602.3On detail 1/C-01 identify all the members. Are there posts? Existing?Provide anchor spacing for detail 5/C-01.