HomeMy WebLinkAbout265383_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103751 PROJECT ADDRESS: 2102 N Westwood Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/11/2020 INITIAL REVIEW 6/23/2020 EXPIRATION 12/8/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ryan Dascanio 3. TEL: (714)996-9900 FAX: VALUATION: $10.00 EMAIL: radascanio@gmail.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. Sheet 1. Revise Index of drawingsto provide correct submitted pages for energy and structural design. Sheet 1. The rear patio is altered and shall be noted in the scope of work with the square footage of the rear patio cover. Provide 2 building proposed elevations: Facing north-east and north-west. Elevation drawings shall include following information: Height dimensions Exterior finishes and materials Exterior building components (walls, roof, doors, windows, etc.) Window types Window header height Height from finish floor to bottom of the opening in egress window(s) Roof slope/pitch Roof venting Top of floor elevations(s) Top of finished grade (referenced to site plan) Attachment/relationship of existing buildings (where applicable) Sheet 7. Show compliance on the drawing. An approved carbon monoxide alarm shall be installed at the following locations: Outside of each sleeping area (e.g. bedroom) in the immediate vicinity of the bedroom(s). In the master bedroom where fireplace occurs. ENERGY Alterations are required to comply with 2019 California Energy Code. Submit an energy compliance package showing compliance with code prescriptive approach OR a complete computer performance analysis. The CF1R forms shall be signed and all pages of the forms shall be incorporated into the drawings. STRUCTRUAL Provide engineering calculation (vertical and lateral supports). Structural calculation must be designed by an Engineer or Architect licensed by the State of California. End of comments. ** No additional plan check comments are marked on the drawings. It is an option, but not required, to pick up submitted plans. However, if you decide to pick up submitted plans, please email Wayne Lee to schedule a plan pick up appointment. For correction resubmittal, no appointment is required. Please submit your document during business hours. Currently, it is 8 am to 12 pm.