HomeMy WebLinkAbout264394_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103488 PROJECT ADDRESS: 1021 1/2 W Chestnut Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/22/2020 INITIAL REVIEW 6/3/2020 EXPIRATION 11/18/2020 RECHECKS: 1.6/18/2020 PROJECT APPLICANT CONTACT PERSON: 2. Bill Cavanaugh 3. TEL: (951)809-2668 FAX: VALUATION: $60,000.00 EMAIL: ToddK@usmodularinc.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.General / Instruction CommentsAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. Police Department (714) 647-5840 -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work.In addition to other fees, a "Park Acquisition and Development Fee" in the amount shownbelow shall be required pursuant to a resolution of the City Council for the Recreation andCommunity Services Agency; net addition of _____2___ bedroom(s).Amount of $7,624.00; net addition of 5 bedroomsAmount of $6,852.59; net addition of 4 bedroomsAmount of $6,188.69; net addition of 3 bedroomsAmount of $4,612.67; net addition of 2 bedroomsAmount of $3,461.87; net addition of 1 bedroom Sheet 1A: Site plan: The proposed ADU building shall be provided with a 5-ft minimum fire distance, measured from the property line to the eave/rake projection. Otherwise, provide details to show at least one-hour fire protection on the underside of eave or provide fire blocking. 2nd Response Comment: Response was insufficient. Building located less than 5-ft from the property line shall comply with the following: Provide one-hour protection exterior wall. One-hour fire-rated wall construction shall be reviewed and approved by the State HCD, and should be the same approved package. Not more than 25% of unprotected openings are allowed when the exterior wall is located less than 5-ft from the property line; and no opening is allowed when the exterior wall is located less than 3-ft from the property line. Non-combustible or ignition resistant materials are not the same as one-hour fire-rated construction. The manufactured home unit with fire-rated exterior wall shall be reviewed and approved by the HCD. Manufactured Home Unit Please provide foundation plans and details to show attachment and support for the manufactured home. Engineering may be required. Plan review will be continue at time of resubmittal and additional comment may be required. 2nd Review Comment: State approved foundation plans – Please provide State approved foundation plans that designed to the current code edition (2019 CBC, CRC, ASCE7-16, etc.).