HomeMy WebLinkAbout265207_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103700 PROJECT ADDRESS: 2729 S Grand Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5897 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: UnKnown OCCUPANCY CLASSIFICATION(S): UnKnown PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/1/2020 INITIAL REVIEW 6/23/2020 EXPIRATION 11/28/2020 RECHECKS: 1.7/13/2020 PROJECT APPLICANT CONTACT PERSON: 2. Andrew Krajacic 3. TEL: (714)394-5383 FAX: VALUATION: $5,000.00 EMAIL: andrew@pmcoc.com FLOOD ZONE: X-0602320278J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS General / Instruction Comments All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please return marked up set of drawings with corrections, if it was picked up. This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)- Fire Department approval on the corrected/final sets of drawings (714) 647-5839 or 647-5700.Sheet A1-1:Please specify building type of construction and whether it’s equipped with Fire Sprinkler or not. 2nd Review Comment: Plan indicated type ‘V’ construction. For clarity, please identify whether it’s type V-B or V-A?Provide a formal letter addressed to the Building Safety Division describing in detail the manufacturing process from material delivery, storage, handling, packaging, and shipping of finish product. Including an equipment list describing use in the process. 2nd Review Comment: Please submit plan along with the letter to the Fire Department for review and approval. On the plan, please show/provide detectable warning (truncated dome) between pedestrian walk (area) and vehicular area (parking area). Provide detail and clearly cross-reference onto the plan. 2nd Review Comment: The transition between the walk and the vehicular area – Please clarify if there were concrete curb between the walk and the parking (loading pay and access aisle). The truncated dome appeared to be located in the vehicular area. Please revise plan to provide truncate dome at the zero between the walk and the vehicular area. Sheet A2-1:Existing restrooms serving the space shall be made accessible to persons with disabilities. Please provide restroom plans and details to show conformance with Chapter 11B, Division 6.2nd Review Comment: Information provided was incomplete. Toilet paper dispenser – please show 7”-9” dimension, measured to the centerline of the dispenser. Provide detail for the grab bars showing elevation and locations. Show 60” clear space for the water closet, measured from wall to the edge of the lavatory. Show water closet elevationPlan was incomplete. Plan review will continue at time of resubmittal and additional comment may be required. Additional plan fees may be required. 2nd Review Comment: 2nd floor plan – please clarify stairways direction (up vs. down). First floor plan – please specify the use of space located to the left of the restroom. Show access and exit for the space.