Loading...
HomeMy WebLinkAbout265756_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103844 PROJECT ADDRESS: 2400 S Grand Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/17/2020 INITIAL REVIEW 6/29/2020 EXPIRATION 12/14/2020 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Cheree Naes 3. TEL: (909)467-8916 FAX: VALUATION: $200,000.00 EMAIL: cnaes@core-states.com FLOOD ZONE: X-0602320278J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process.- Fire Department approval on the corrected/final sets of drawings (647-5839 or 647-5700) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039)Provide a Special Inspection Schedule on plans; include all the items requiring special inspection, in addition, to the required Special Inspection Statement per section 1704. E.g. Concrete, post-installed anchors, soils...Submit a signed and stamped letter from the soils engineer indicating that he/she has reviewed the foundation plans and concurs that the plans are in conformance with the soils report recommendations.Sheet S1.0. Update geotechnical report number in the foundation note #1 per submitted soils report which is No. 20060-01.Incorporate geotechnical observation and testing procedures on plan. The requirements are located on section 13 on the page 8 of the geotechnical report.Delete detail 9 on structural sheet S3.0. The light pole footing does not apply to this permit.