HomeMy WebLinkAbout267011_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104180 PROJECT ADDRESS: 1515 1/2 N French St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/30/2020 INITIAL REVIEW 8/27/2020 EXPIRATION 1/26/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Benito Corona 3. TEL: (714)371-7176 FAX: (914)339-8869 VALUATION: $45,000.00 EMAIL: bcndesigner@sbcglobal.net FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). Please revise plan to show the 1/2 (half) address for the proposed ADU. Sheet A-1: Scope of work – please include the demolition of the existing storage. Sheet A-1: Plumbing fixture flow rate – Please revise notes to limit the laundry faucet and lavatory faucet to 1.2 gallon per minute. Sheet A-1: Site plan – please show surface drainage away from all buildings. Show slope and pattern. Minimum 5% away from the building wall; 2% at impervious finish surface. Please revise job address to the 1/2 (half) address for ADU. Sheet A-2: Please provide/show a smoke alarm outside of the bedroom. Sheet A-2: Please specify roofing material (existing and new). On the plan, please show/provide attic access and vents. Sheet GRN-1: Please update CalGreen sheet for the 2019 California Green Code. Sheet T-24: Title 24 calculation and Compliance forms – Please update Title 24 calculation to the 2019 Residential Compliance. Provide calculation for the 2x6 ceiling joists spans 19-ft with new ceiling finish and attic insulation.