HomeMy WebLinkAbout267200_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102104245 / 46 PROJECT ADDRESS: 1202 S Pacific Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/5/2020 INITIAL REVIEW 9/16/2020 EXPIRATION 2/1/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Soung Lieu 3. TEL: (310)782-5195 FAX: VALUATION: $10,000.00 EMAIL: soungl@yahoo.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.General / Approval Requirement:All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). Sheet T-01: Occupancy group – Please revise occupancy group to specify R-2 for apartment buildings. Sheet A-01: Exit stairways shall be placed at a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the building. Please revise plan accordingly. (CBC 1007.1.1) Guardrails detail: Openings in handrails and guardrails – please revise note to delete note stating “or larger”. The opening shall not allow the passage of a 4” sphere diameter at the guardrails. Stair riser and tread: Please revise plan to provide 7” maximum risers and 11” minimum treads. (CBC 1011.5.2) On the plan, please show top and bottom landing – show dimensions (48” minimum). Please show handrail extensions at top and bottom of stairway. 12” horizontally at top landing and 12” plus tread depth. Similar to figure below: