HomeMy WebLinkAbout267383_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104306 PROJECT ADDRESS: 3400 W Segerstrom Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/12/2020 INITIAL REVIEW 9/17/2020 EXPIRATION 2/8/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Eric Liwski 3. TEL: (949)596-7362 FAX: VALUATION: $2,000,000.00 EMAIL: eliwski@synarcstudio.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS General / Approval Requirement All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A-0.00:Occupancy groups: Please clarify what type of ‘S’ occupancy classification of the proposed T.I. There were two sheets of A-0.00. Please do not provide duplicate information. Drawing Index: Please note Mechanical, Plumbing, Electrical and Refrigeration are under separate review. Drawing Index: Structural plans are missing from the plan sets. Please provide structural plans for review and approval. Sheet A-1.01:Please specify the use of space for the area adjacent to the improvement space. Accessible route: referenced to the prior approved permit was insufficient. Please show an accessible route from the public sidewalk to the building primary entrance; and from the accessible parking stall(s) to the building entrance. Provide/show an accessible path of travel from the accessible entrance to the area of alteration/improvement. Accessible route shall be 48” minimum wide with 5% maximum slope measured in the direction of travel and 2% maximum cross-slope. Show on the plan. Fences and gate: Please clearly clarify whether the fences and gates are existing or new. Revise plan accordingly. All required exits shall be continuous to a public way in accordance with Section 1009.2. Please show on the plan. Building Analysis: The first floor building area is 54,049 square feet:Please provide allowable building area in accordance with Section 506. On the plan, please clearly identify/show location of the 8,594 square feet of first floor office area vs. 45,437 square feet warehouse. Section 03/A-7.1 called out on the Enlarged plan 01 was not applicable. Sheet A-7.1 was not provided. Please coordinate and revise plan accordingly. Sheet A-2.00.DDemo plan: Demo of existing concrete slab adjacent to existing footing – Please show how existing footing will be protected. Provide minimum setback from existing wall and columns for existing footing protection. Sheet A-2.01On the plan, please show/specify the use of space for the area adjacent to the improvement area. Due to construction of the new cold storage area, please provide complete egress plan for the entire building, including the area without work. All required exits shall be continuous to a public way in accordance with Section 1009.2. Please show on the plan.Provide detail and specification for the slab insulation. Provide listing report. Provide termite protection/mitigation. Sheet A-9.01: RampPlease provide complete ramp information to show compliance with Section 11B-405, including handrails. Sheet AD-9.01General Notes – Please revise notes to specify the current code edition, 2019. Keynotes #5: details referenced to sheet A-10.1 were not applicable. Please coordinate and revise plan accordingly. Structural Review Comment:Structural plans and details were not provided. Plan review will continue at time of resubmittal. Provide foundation plan and details.Provide roof and ceiling framing plans. Provide details for wall openings. Provide attachment details for new wall. Provide structural slab and details for the ground-mounted equipment.Etc.