HomeMy WebLinkAbout266313_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102103974-75 PROJECT ADDRESS: 2531 S Salta St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: Aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/6/2020 INITIAL REVIEW 8/13/2020 EXPIRATION 1/2/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Araceli Maciel 3. TEL: (714)285-1121 FAX: VALUATION: $42,000.00 EMAIL: aadrafting@msn.com FLOOD ZONE: X-0602320259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.Sheet A-1Please identify the new address “2531 ½ Salta Ave, Santa Ana CA 92704” on the new accessory dwelling unit (ADU).Separate scope of work on each address. For example, the scope of work on address 2531 Salta Avenue shall include room addition, covered patio and windows replacement. The scope of work on address 2531 ½ Salta Avenue shall include conversion of existing garage to a new accessory dwelling unit.Complete information under Consultants.Under Special Inspection Required, cross reference special inspection program on sheet S3.Sheet U1Specify smoke alarm outside the doorway of bedroom one.Sheet S-2Detail 15/S5 is referenced at the patio footing but the detail is missing on sheet S5.Shear walls notes and crossed-reference details are illegible on the southern exterior wall of the accessory dwelling unit.Slab-on-grade note specifies 10 mil vapor barrier. However, detail 6/S5 specifies 6 mil vapor barrier.Verify two crossed-reference detail numbers on the star (*) symbol on the foundation plan.Sheet S-3See comment number 7. In addition, the shear wall at the living room is illegible.The four-foot dimension is shown twice on the porch.Insulation value at the vaulted ceiling is specified as “R-38” on CF-1R page 5. There are few places on Section A and framing plan which specify the insulation value of R-30.Section A indicates ledger size and connection detail at the modified roof rafter end connection. Please match this condition in detail 12/S5.Section A indicates roof insulation to be installed “alternate sides”. What does it mean?Provide structural connection detail where purlin-bracing members connect to the top of the bearing wall.On Section B, specify the total overhang distance from the face of the exterior wall.On the vaulted ceiling section, provide a detail to show the minimum one-inch gap clearance for ventilation.