HomeMy WebLinkAbout265865_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103877 PROJECT ADDRESS: 2510 S Bristol St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/23/2020 INITIAL REVIEW 7/6/2020 EXPIRATION 12/20/2020 RECHECKS: 1.8/11/20 PROJECT APPLICANT CONTACT PERSON: 2. Ken Fang 3. TEL: (909)569-2069 FAX: VALUATION: $80,000.00 EMAIL: CND9@me.com FLOOD ZONE: X-0602320259J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS General / Instruction Comments All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Please note on plan: This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A-1:For clarity, please show dimensions for interior walls so that wall and openings can easily located. 2nd Review Comment: Please show/provide maneuver space complying with Section 11B-404.2.4 at all door (interior and exterior doors), such as at door between hallway and cashier area; and door between foot message room and break room. Hallway leading to the accessible restroom: Please show/provide minimum clear of 44” between the wall and column. Please show/provide additional exit sign at hallway leading to the exit door(s). 2nd Review Comment: Response was incomplete. Please provide additional illuminated exit signs and tactile exit signs at the following locations so that a person can see two exits at any occupiable location. At hallway outside of therapy room #2 leading to a second exit at waiting area. At the door opens between the foot message only area and the waiting area.At exit doorways of the foot message room (6 chairs room). Revise ceiling plan accordingly. Please show/provide minimum 36” clear at least on one side of the equipment (chair / table). 2nd Review Comment: Please comply. At the open foot message area – Please show/provide wheelchair space at the message chair. 2nd Review Comment: For clarity, please show required dimensions for the wheelchair space on the plan.