HomeMy WebLinkAbout267072_2_Corrections.docxSPC
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101104198
PROJECT ADDRESS:
2700 S Hotel Terrace Dr
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V A, SPK
OCCUPANCY CLASSIFICATION(S):
B, R-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/3/2020
INITIAL REVIEW
9/8/2020
EXPIRATION
1/30/2021
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Robert Ko
3.
TEL:
(626)497-1300
FAX:
VALUATION:$20,000.00
EMAIL:
charob58@gmail.com
FLOOD ZONE:X-0602320278J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTSThe applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans
should be submitted to expedite the process.PLAN CHECK COMMENTS:Sheet A0.3. Detail 1. Add marking of borderlines on the perimeter of the access aisles.Sheet A0.3. Detail 1. Revise wall mounted sign height to minimum 60” above finish surface.Sheet A-1.1. Clarify the location of the “tow-away” sign on the site plan.Sheet A-1.1. Site plan. There are 4 accessible parking spaces provided on the north side of the pool. Revise note on the site plan to match the number of the accessible parking spaces provided. (5 in the note)Sheet A-1.3. Add borderline marking on the accessible parking space. Minimum 18 feet long depth is required.Sheet A-1.3 and A-1.4. Add marking of borderlines on the perimeter of the access aisles.Sheet A-1.3and A-1.4. Provide detectable warnings (truncated domes) at the boundary between the access aisle and ramp bottom landing. Detectable warnings that are 36 inches minimum in depth extending the full width of the pedestrian path or cut-through less than 2 inches maximum on each side202, §11B-247.1.2.5, §11B-705.1.2.5Provide detectable warning details showing compliance with the following. Detectable warning surfaces at transit boarding platform edges, bus stops, hazardous vehicular areas, reflecting pools, and track crossings shall comply with Section 11B-705.1.1.3.1. §11B-705.1.1.3Sheet A-1.3 and A-1.4.Add note to plan that “Detectable warning surfaces shall be yellow and approximate FS 33538 of Federal Standard 595C. §11B-705.1.1.3.1”.Sheet A-1.3and A-1.4.Revise the ramp design not to exceed 8.33% in the running slope direction. All 3 new ramps exceeds 8.33% slope. For example, the ramp on sheet A-1.3 has slope = 8”/7’7”=8.79% > 8.33% which does not comply.Sheet A-1.3. Show dimensions of the ramps on site plan. The 48” minimum width is required for the accessible ramps.Sheet A1.4. Detail 1. Revise the location of the top handrail extension. The hand rail extension is measured from the edge of the top landing. Ramp handrails shall extend horizontally above the landing for 12 inches minimum beyond the top and bottom of ramp runs.