Loading...
HomeMy WebLinkAbout264819_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103608 PROJECT ADDRESS: 838 E First St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 5/28/2020 INITIAL REVIEW 6/11/2020 EXPIRATION 11/24/2020 RECHECKS: 1.7/30/2020 PROJECT APPLICANT CONTACT PERSON: 2.9/30/202 Gonzalo Guillen 3. TEL: (714)667-0892 FAX: VALUATION: $100,000.00 EMAIL: gplanos@sbcglobal.net FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS General / Instruction: All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714) 573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - County of Orange Health Department approval on the corrected/final set of drawings ((714) 433-6000) - School District Compliance Certificate; a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of work. Refer to the attached handout.Sheet T-1:Provide designer and architect of record contacts information on the plan. Sheet AA.10:On the plan, please show/provide an accessible route from the public sidewalk to the building primary entrance. Accessible route shall be maximum of 5% slope, measured in the direction of travel, and 2% maximum cross-slope. 2nd Review Comment: Response was incomplete. Please clarify note indicated “36” minimum wide detectable warning strip” at the marking path of travel. Please specify accessible route shall be 5% maximum slope, measured in the direction of travel, 2% maximum cross-slope, and 48” minimum wide. 3rd Review Comment: The detectable warning is only required at the curb ramp – please revise plan to remove the note “detectable warning” along the accessible path of travel. 5-ft minimum landing and maneuver space is required at the new exterior door – please coordinate with floor plan. The 5-ft maneuver space shall not encroach into the accessible parking access aisle. 3rd review Comment: Please clearly show dimensions for the maneuver space at door. Sheet AA.14:The existing curb ramps now would become a pedestrian ramp and shall comply with Section 11B-405. Please revise plan and details to show compliance with Section 11B-405. 2nd Review Comment: Please coordinate the existing finish floor elevation at the existing ramps. Ramp shall comply with Section 11B-405. 3rd Review Comment: Existing curb ramp have to be modified to comply with door landing and ramp. Level the existing curb ramp and relocate door may be considered. New exterior doors: Please show/provide a level landing and maneuver space on both side of the door. Show minimum maneuver dimensions per Section 11B-404.2.4. 2nd Review Comment: Please coordinate with site plan. Door landing and maneuver space shall not encroach into the accessible access aisle. 3rd Review Comment: Please coordinate door landing and maneuver space with comment above. Sheet AA.02: Egress/exiting plan:Please provide an egress plan / exiting plan for the proposed tenant improvement building.2nd Review Comment: Please provide enlarged plans to be legible and clearly show visible exit signs (see marked up plan for typical locations. Space/room with single exit shall be limited to 100-ft travel distance. 3rd Review Comment:Common path travel distance for storage room shall be measured along the wall from the farthest point; second exit door may be required due to the travel distance. Plan must be legible and drawn to scale. Please enlarge plan and specify drawing scale on plan. Title 24: Energy ConservationResolvedCalifornia Green Building CodeResolved Sheet S1.1:New wall construction at existing curb ramp – Please provide new concrete curb at the existing ramp to create a level sill plate. Provide detail and clearly cross-reference detail onto the plan. 2nd Review Comment: Please coordinate with architectural plan for the slab work at the existing curb ramps. There will be required slab works to make slab finish elevations in compliance with accessibility required.