HomeMy WebLinkAbout267200_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
102104245 / 46
PROJECT ADDRESS:
1202 S Pacific Ave
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/5/2020
INITIAL REVIEW
9/16/2020
EXPIRATION
2/1/2021
RECHECKS:
1.10/13/2020
PROJECT APPLICANT CONTACT PERSON:
2.
Soung Lieu
3.
TEL:
(310)782-5195
FAX:
VALUATION: $10,000.00
EMAIL:
soungl@yahoo.com
FLOOD ZONE: X-0602320257J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.General / Approval Requirement:All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
Sheet A-01:
Stair riser and tread: Please revise plan to provide 7” maximum risers and 11” minimum treads. (CBC 1011.5.2)
2nd Review Comment: Sheet A-01 – Please revise notes to specify minimum 11” treads.
On the plan, please show top and bottom landing – show dimensions (48” minimum).
2nd Review Comment: On the plan, please show minimum 48” clear level landing at the bottom of the stairway, and show/provide protection (barrier) from vehicles.
Please show handrail extensions at top and bottom of stairway. 12” horizontally at top landing and 12” plus tread depth. Similar to figure below:
2ndReview Comment: Handrails detail provided on sheet S-1 was insufficient. Please provide the following:
Please show handrails height at 34”-38” from finish floor.
Show guardrail height at 42” minimum above finish floor.
Show handrail extension at bottom landing as showed above.