Loading...
HomeMy WebLinkAbout268942_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101104851 PROJECT ADDRESS: 1026 1/2 N West St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/5/2020 INITIAL REVIEW 10/20/2020 EXPIRATION 4/3/2021 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Albert Luu 3. TEL: (714)858-5959 FAX: VALUATION: $65,000.00 EMAIL: albert.luu@hotmail.com FLOOD ZONE: A-0602320143J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.General and Approval RequirementAll items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). This project is in a special flood hazard area designated on the flood insurance rate map (FIRM) as zone A or AE. This zone requires that the lowest finish floor elevation (including basement) of the structure shall be at (or above) base flood elevation determined by a hydrology study for the A zone, All elevations must be referenced to the National Geodetic Vertical Datum. Reference should be made to the Flood Plain Management Ordinance, Santa Ana Municipal Code, Chapter 7, for complete requirements. Drawings shall show compliance with said ordinance including noting flood zone and finish floor elevation." Project Address: Please use ½ address. Sheet A1: Site plan: Please revise plan to show grade slope minimum 5% away from the building foundation wall; 2% on the paved or concrete surface. Sheet A2: Please relocate the new water heater to the outside so it can be accessible for the ADU. Exterior steps: Please provide handrails when four or more steps are provided. Please show handrails and guardrails and provide detail on the plan. Handrails shall not be less than 34” or more than 38” above the noising of tread. Handrail shall be continuous the full length of the flight. Guardrail shall be 42” in height. Openings in guardrails shall not allow passage of a 4” diameter sphere. Please show rises and runs dimensions (7.75” maximum rise, 11” treads). Wall between ADU and existing residence should be protected with one-hour construction. Please show on plan and provide one-hour wall construction details. Clearly cross-reference detail onto the plan. Sheet SD-1: Detail 01: please provide the following for wood protection again concrete – Specify corrosion resistance flashing. Provide/show metal weep screed at the bottom end of the flashing Please provide air gap between the concrete and existing wall studs, and the air gap shall be sealed/filled with caulking sealant.