HomeMy WebLinkAbout265948_5_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101103907 PROJECT ADDRESS: 1010 N Tustin Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U, A-3, B, E PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/24/2020 INITIAL REVIEW 7/9/2020 EXPIRATION 12/21/2020 RECHECKS: 1.8/10/20 PROJECT APPLICANT CONTACT PERSON: 2.8/31/20 Lonnie Waldner 3.9/29/20 TEL: (909)983-7777 FAX: VALUATION: $370,000.00 EMAIL: lonnie@matlockdb.com FLOOD ZONE: X-0602320164J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS General / Instruction All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Resubmit 2corrected sets of plans and 2 copies of structural calculationsPlease return marked up set of drawings with corrections, if they are picked up. The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A1.1:The proposed shade structure is considered a new structure. Please provide building code analysis to show compliance with the building allowable area per Chapter 5, and fire protection per Chapter 7 of the 2019 California Building Code. 2nd Review Comment: Either revise job description and plans to show/specify the shade (covered) structures will be under a separate permit application, or provide building code analysis to show compliance with the building allowable area per Chapter 5, and fire protection per Chapter 7, CBC. 3rd Review Comment:The information provided was incomplete. There are existing buildings on the same lot and adjacent to the proposed structure. The allowable area calculation/analysis shall consider the building area of the existing buildings. (503.1.2; 3101.1; 3102.4)4th Review Comment: Scope of work changed – To be consistence, please provide the following:Sheet T-1: Scope of work – Please revise scope of work to specify temporary overhead shade sail structure. Sheet T-1: Temporary shade sail structure – Please specify “The structure shall erected for a period of less than 180 days, and shall comply with the California Fire Code”. Final Plans and Documents Final plans and calculations shall be stamped, signed, and dated by the architect and engineer of record